Wiring

Type 8025 / 8035

8.2.

Wiring the 8025 compact version and the 8035 with a 4 pin male
fixed connector

1

2

3

1: V+ (12-36 V DC)

2: Positive pulse output

3: L- ( 0 V DC)

: Negative pulse output

Fig. 18: Pin assignment of the 4 pin male fixed connector

1

2

3

4

→

Unscrew the nut 1 of the cable gland.

→

Remove the terminal block 3 from the housing 2.

→

Insert the cable through the nut 1 then through the gasket
4, through the cable gland and finally through the housing
2.

→

Connect the wires on terminal block 3. See "Fig. 18", "Fig.
20"
and "Fig. 21".

→

Position the terminal block 3 in steps of 90° then put it back
into the housing 2, pulling gently on the cable so that the
wires do not clutter the housing.

→

Tighten the nut 1 on the cable gland.

6

5

→

Place the seal 5 between the connector and the fixed con-
nector on the device and then plug the 2508 connector into
the fixed connector.

→

Insert and then tighten the screw 6 to ensure tightness and
correct electrical contact.

Fig. 19: Assembling the female connector type 2508 (supplied)

→

Wire the electrical supply and the current output using one of the wiring plans of "Fig. 20".

300 mA

+

-

12-36 V DC

+

-

(*)

1

3

2

L+

L-

Power supply

4-20mA input at external

instrument

4-20mA input at external

instrument

300 mA

+

-

12-36 V DC

+

-

(*)

1

3

2

L+

L-

Power supply

(*) If direct earthing is not possible, insert a 100 nF / 50 V condensator between the negative terminal of the voltage supply and the earth.

Fig. 20: Possible wiring of the current output of a compact version with male fixed connector