Recommendations on installing an 8076 on a pipe, Figure 13), Figure 14) – Burkert Type 8076 User Manual

Page 28

Advertising
background image

26

Installationandwiring

SE36

S030

1

2

3

SE36

S070

1

2

→

1: Insert the electronic module in the sensor holder.

→

2: Turn the electronic module by a quarter turn.

→

3: Secure the electronic module and the S030 fitting only, by
tightening the screw with a suitable tool to a max. tightening
torque of 1 Nm.

Figure 13 :

Assembling the SE36 and the fitting S030 or S070

A

B

→

Check that there is a seal on the fitting and that it is not
damaged. Replace the seal if necessary.

→

Place nut A on the fitting and insert circlip B into the groove.

→

Carefully insert the device into the fitting. If assembly is
correct, the device can no longer rotate on itself.

→

Secure the unit with nut A, tightening only by hand.

Figure 14 :

Installation of flowmeter 8026 into the fitting S020

→

Set the K factor parameter (see chap. 9.13.5) or have it determined through a teach-in procedure.

8.2.2.

recommendations on installing an 8076 on a pipe

→

Install the fitting S070 on the pipe in such a way that the oval gear axes are in the horizontal plane, as shown
in Figure 15.