Maintenance and troubleshooting, Safety instructions, Cleaning the device – Burkert Type 8076 User Manual

Page 65: If you encounter problems

Advertising
background image

63

Maintenanceandtroubleshooting

10.

mAinTenAnce AnD TroubleshooTinG

10.1. safety instructions

danger

risk of injury due to high pressure in the installation.

• Stop the circulation of fluid, cut off the pressure and drain the pipe before loosening the process connections.

risk of injury due to electrical voltage.

• Shut down and isolate the electrical power source before carrying out work on the system.
• Observe all applicable accident protection and safety regulations for electrical equipment.

risk of injury due to the nature of the fluid.
• Respect the prevailing regulations on accident prevention and safety relating to the use of aggressive fluids.

Warning

risk of injury due to non-conforming maintenance.
• Maintenance must only be carried out by qualified and skilled staff with the appropriate tools.
• Ensure that the restart of the installation is controlled after any interventions.

10.2. cleaning the device

The device can be cleaned with a cloth dampened with water or a detergent compatible with the materials the
device is made of.

Please feel free to contact your Bürkert supplier for any additional information.

The fouling of the paddle-wheel may result in a drift of the flow rate measurement.

→

Clean the paddle-wheel according to the type of fouling.

10.3. if you encounter problems

red
leD

current
output

transistor
output

icon message dis-

played in the
info menu

possible cause

recommended action

ON

22 mA

1)

depending
on
thresholds

ERR

+

"Sensor not
found"

The connection to the
measurement module
is interrupted.

→

Switch the power supply
off then on again.

→

If the error persists, return
the device to Bürkert.

English

Type 8026- 8036- 8076

Advertising
This manual is related to the following products: