Fluid Components International FLT Series User Manual

Page 10

Advertising
background image

FLUID COMPONENTS, INTL

CHAPTER 1 - GENERAL INFORMATION

FLTÔ Series FlexSwitchÔ

1 - 2

Doc. No. 06EN003246 Rev. B

Technical Specifications

•

Process Connection

3/4 inch male NPT standard. 1 inch BSP, 1 inch
male NPT, 1/4 inch male NPT (FLT93-F only),
flanged mounting, spool piece with 3/4 inch NPT tee
or retractable sensing element available.

•

Insertion Length

Beginning as low as 0.9 inches (23 mm). Standard as
well as custom lengths are available.

•

Sensing Element Material

All wetted surfaces are 316 Stainless steel, with all-
welded construction. Hastelloy C-276, Monel 400
and electro-polished stainless steel surface preparation
optionally available. Titanium is optionally available
on the FLT93-S configuration only.

•

Operating Temperature

Control circuit:

Ambient: -40 to 140°F (-40 to 60°C).

Sensing element:

Standard temperature configuration:

-40 to 350°F (-40 to 177°C).

Medium temperature configuration:

-100 to 500°F (-73 to 260°C).

High temperature configuration:

-100 to 850°F (-73 to 454°C).

•

Operating Pressure

Hydrostatically proof pressure tested to 3500 psi
(241.3 bar) at 70°F (21.1°C). De-rated with
temperature, the maximum recommended operation
service is 2350 psi (162 bar) at 500°F (260°C).
Higher ratings available with special construction and
test certification.

•

Flow Range

From 0.01 to 5 fps (0.006 to 0.15mps) with fluid or
0.25 to 120 fps (0.076 to 38.1 mps) with gas,
depending upon model.

•

Signal Output

Buffered voltage output available as a standard for
temperature and either flow or level/interface. The
minimum load impedance is 100 K ohms.

•

Accuracy

Switch point accuracy:

Up to ± 2% of the switch point
velocity.

Monitoring accuracy:

±5 % reading (or ±0.04 fps, 0.012 mps,
which ever is larger for liquid applications
and ±2 fps, 0.061 mps, which ever is larger
for gas applications).

Level accuracy:

Down to ±0.1 inch (±0.25 cm)

Temperature accuracy:

Up to ±2 °F, (±1.1°C) depending upon
application. Higher accuracy is available
with factory calibration.

•

Repeatability

±0.5% of monitor reading.
Up to ±0.05 inch (±0.13 cm) of level depending on
model.
±1.0°F, (±0.56°C) of temperature.

•

Response Time

Alarm set point may be set as low as 0.5 seconds.
Alarm reset may be as low as 2.5 seconds.

•

Input Power

Field or factory selectable for 115 Vac ±15V, 13VA
100 mA maximum; 230 Vac ±30V 14 VA 50mA
maximum; 24 Vac +2 to -6V 12.5 VA 485 mA
maximum; or 24 Vdc +6, to -3V, 7 watts, 230 mA
maximum. 100 Vac ±10 V is optionally available.
All AC Power is 50 to 60 Hz. Power applied is
indicated by an LED.

•

Heater Power

Field or factory selectable for specific fluid service
requirements.

•

Relay Rating

Dual alarm SPDT or single alarm DPDT field
configurable 6 amp resistive at 240 Vac, 115 Vac or
24 Vdc. Options available on auxiliary relay board
are 2 amp or 10 amp DPDT, plastic sealed, 0.5 amp
DPDT hermetically sealed.

•

Enclosure

Hazardous Location Class I, II, Div. 1, 2 Groups B, C,
D, E, F, and G. NEMA type 4X optionally available.

•

Electronics

Part Number: 5294- _ _ _ FlexSwitch™

•

Agency Approvals

Factory Mutual and CSA system approved.
CENELEC (hazardous location only) system
approved. Approved CE marking.