Fluid Components International CMF Series Manual Wiring Diagrams User Manual

Fluid Components International Equipment

Advertising
background image

Electrical connect.

Fluid Components Intl

Document 06EN003327 Rev. -

45

FlexCOR

Model CMF Series

6.1

Signal Transmitter

IP 67 and 19”

(terminal board
083H4260,

083H4253 &

083H4255)

Installation

1) Mains supply 115 to 230 V a.c. from building installation Class II. A switch or circuit-breaker

(max. 15 A) shall be included in the building installation. It must be in close proximity to the
equipment and within easy reach of the OPERATOR, and it shall be marked as the

disconnecting device for the equipment.

2) Protective conductor terminal. Required cable min. AGW16 or 1.5 Cu.

The insulation between the connected mains supply and 24 V a.c./d.c. supply for the flow-

meters, models 24 V a.c./d.c. shall at least be rated with double or reinforced insulation at
mains voltage.
For field wiring installation National Installation Code shall be met of the country, where the

flowmeters are installed.

Digital output

If the internal resistance of the loads exceeds 10K ohms, it is recommended to connect an

external 10K ohms load resistor in parallel to the load.

6.

Electrical connection