Signet 2724-2726 and 2734-2736 Series DryLoc pH and ORP Electrodes

English

Operating Instructions

The Signet 2724-2726 and 2734-2736 Series of pH and ORP electrodes are designed
to minimize maintenance time and maximize value.

The unique DryLoc

®

connector provides quick assembly and a secure

connection featuring gold-plated contacts and an O-ring seal.

The patented design features a lengthened reference chamber pathway to
extend the operational life of the electrode.

Wetted materials are selected to withstand a wide array of industrial applications.

Multiple mounting features address the need for installation fl exibility.
These electrodes can be threaded into ¾ in. NPT or ISO 7/1 R¾ inch pipe fi ttings,
submerged in a tank, or mounted into familiar Signet installation fi ttings.

To build a stand-alone, self-contained pH control system, combine the
2724-2726 electrodes with a 2760 pH Preamplifi er and add a 8750 pH/ORP
Transmitter to move your control capability to the next level.

Combine the 2427-2726 or 2734-2736 electrodes with the
2750 pH Sensor Electronics to provide a 4 to 20 mA loop to a
Programmable Logic Controller (PLC), SCADA system, or datalogger.

• For

more

fl exibility and unique features, pair the 2724-2726 or 2734-2736 series

with a 2750 pH/ORP Sensor Electronics and the new 9900 Transmitter.

Connect up to six 2724-2726 or 2734-2736 electrodes to one 8900 Multi-Parameter
Controller with six 2750 pH/ORP Sensor Electronics using digital (S

3

L) serial data

output for a truly amazing set of features, options, and measurements.

The 2724-2726 electrodes are recommended for general purpose applications.

The 2734-2736 electrodes are recommended for harsh applications.

The 2734-2736 electrodes utilize advanced reference technology to extend
electrode life in all applications.

Description

2724 & 2725
2734 & 2735

Flat Glass

Electrode

2726 & 2736

Protected

Bulb Glass

Electrode

Table of Contents

Description ............................................................................................ 1
Warranty Statement .............................................................................. 2
Product Registration ............................................................................. 2
Chemical Compatibility ......................................................................... 2
Safety Information................................................................................. 2
Dimensions ........................................................................................... 3
Specifi cations........................................................................................ 3
In-Line Installation................................................................................. 4
Low Conductivity Installation ................................................................ 4
Signet Installation Fittings ..................................................................... 5
Removing from In-Line Installation ....................................................... 5
Submersible Installation........................................................................ 5
pH System Calibration .......................................................................... 6
ORP System Calibration ....................................................................... 6
Electrode Date Code ............................................................................ 7
Electrode Care and Application ............................................................ 7
Cleaning................................................................................................ 7