Processpro editing procedure, Step 1, Step 2 – GF Signet 8350 Temperature Transmitter User Manual

Page 5: Step 3, Step 4, Step 5, Step 6, Step 3: finished editing, Step 5: made an error

Advertising
background image

5

8350-3 Temperature Transmitter

Output1 Setpnt:

2

0.00

°C

Output1 Setpnt:

1

0.00

°C

ENTER

Output1 Setpnt:

1

0

.00

°C

Output1 Setpnt:

1

9

.00

°C

Output1 Setpnt:

Saving

Output1 Setpnt:

19.00

°C >

20.00

°C >

Output1 Setpnt:

>

Switch ID:

Notes on Steps 5 and 6:
• All output functions remain active during editing.
• Only the fl ashing element can be edited.
• ► key advances the fl ashing element in a continuous loop.
• Edited value is effective immediately after pressing ENTER key.
• If no key is pressed for 10 minutes unit will restore the last saved value and return to step 3.
• Step 6 (pressing ENTER key) always returns you to Step 3.
• Repeat steps 3-6 until all editing is completed.

Notes on Step 2:
If no key is pressed for 5 minutes while display is showing "Enter
Key Code", the display will return to the VIEW menu.

Notes on Steps 3 and 4:
• Refer to pages 6 and 7 for complete listing of menu items and their use.
• From the Step 3 display, pressing the ▲ and ▼ keys simultaneously will return

the display to the VIEW menu.

• If no key is pressed for 10 minutes, display will also return to the VIEW menu.

ProcessPro Editing Procedure:

Step 1.

Press and hold ENTER key:

• 2 seconds to select the CALIBRATE menu

• 5 seconds to select the OPTIONS menu.

Step 2.

The Key Code is ▲-▲-▲-▼ keys in sequence.

• After entering the Key Code, the display will show the fi rst item in the selected menu.

Step 3.

Scroll menu with ▲ or ▼ arrow keys.

Step 4.

Press ► key to select menu item to be edited.

•

The

fi rst display element will begin fl ashing.

Step 5.

Press ▲ or ▼ keys to edit the fl ashing element.

• ► key advances the fl ashing element.

Step 6.

Press ENTER key to save the new setting and return to Step 3.

2s

5s

ENTER

OPTIONS

CALIBRATE

VIEW

Press &
hold for
access:

Step 5

Step 6

Notes on Step 1:
• The View Menu is normally displayed.
• The CALIBRATE and OPTIONS menus require a KEY CODE.

Step 4

First item in CALI-
BRATE menu

Step 3

Step 3: Finished Editing?

Press the ▲ and ▼ keys simultaneously after saving
the last setting to return to normal operation.

Press the ▲ and ▼ keys simultaneously while
any element is fl ashing. This will recall the last
saved value of the item being edited and return
you to Step 3.

Step 5: Made an Error?

CALIBRATE: ----

Enter Key Code

CALIBRATE: *---

Enter Key Code

CALIBRATE: **--

Enter Key Code

CALIBRATE: ***-

Enter Key Code

>

Switch ID:

Advertising