Trouble shooting guide – Hydrotech 5600 SXT Valve Carbon & Multi-Media Filter Operation Manual User Manual

Page 11

Advertising
background image

9

Trouble Shooting Guide

PROBLEM

CAUSE

CORRECTION

1. Filter bleeds taste and odor

A. Bypass valve is open

A. Close bypass valve

or sediment

B. Electrical service to unit has

B. Assure permanent electrical service (check

been interrupted

fuse, plug or switch)

C. Defective or stripped media bed

C. Replace media

D. Quality of water has worsened

D. Have water sample analyzed to determine

any change

E. Filter capacity too small

E. Replace with larger unit or add another filter

F. Filter not backwashing enough

F. Be sure flow control is not clogged or drain

line restricted. Be sure water pressure has
not dropped and that pump has sufficient
capacity

G. Excessive water usage -

G. Increase frequency of regeneration. Make

calendar clock models

sure there are no leaks in toilets or sinks

2. Filter fails to regenerate

A. Electrical service to unit has

A. Assure permanent electrical service (check

been interrupted

fuse, plug or switch)

B. Timer is defective

B. Replace timer

C. Power failure

C. Reset time of day

D. Timer motor does not run

D. Replace defective motor

3. Filter regenerates every day

A. Faulty gear train

A. Check the mechanical linkage on the timer

control to eliminate possible binding in the
gear train

4. Loss of water pressure

A. Iron or turbidity build-up in filter

A. Clean control and treat bed with Iron Out.

Increase frequency of regeneration

B. Filter not regenerating often

B. Increase frequency of regeneration

enough

C. Not enough water volume or

C. Correct water supply problem

pressure to backwash properly

5. Loss of media through

A. Air in water system

A. Assure that well system has proper air

drain line

eliminator control. Check for dry well
condition

B. Backwash rate too fast

B. Check drain flow control for proper flow

rates

6. Drain flows continuously

A. Foreign material in control

A. Remove piston assembly and inspect bore.

Remove foreign material and check control
in various regeneration positions

B. Timer motor stopped or jammed

B. Replace timer motor