Installation Instructions

All government codes and regulations governing the installation of these devices must be observed.
CAUTION: If the ground from the electrical panel or breaker box to the water meter or underground copper pipe is

tied to the copper water lines and these lines are cut during installation of the Noryl bypass valve and/or poly pipe, an

approved grounding strap must be used between the two lines that have been cut in order to maintain continuity. The

length of the grounding strap will depend upon the number of units being installed and/or the amount of copper pipe

being replaced with poly. See Figure 1.
In all cases where metal pipe was originally used and is

later interrupted by poly pipe or the Noryl bypass valve as

in Figure 1 or by physical separation as in Figure 2,
An approved ground clamp with no less than #6 copper

conductor must be used for continuity, to maintain proper

metallic pipe bonding. Check your local electrical code for

the correct clamp and cable size.
Check your local electrical code for the correct clamp and

cable size.

1. Determine the best location for your water softener,

bearing in mind the location of your water supply lines,

drain line and 120 volt AC electrical outlet. Subjecting the

softener to freezing or temperatures above 110°F (43°C)

will void the warranty.

Media Installation (When Necessary)

• Remove the valve from the mineral tank.

• Temporarily plug the open end of the riser tube to ensure

that no resin or gravel falls down into the distribution.

• Fill mineral tank one quarter full of water to protect

distribution during gravel installation.

• Slowly and carefully add the gravel support bed and the

softener or filtration media leveling each layer as it is

placed into the tank.

• Unplug the riser tube, carefully position the valve over it and turn the valve into the threads in the fiberglass tank,

tightening securely into tank. Note: Ensure that the internal O-ring in the valve fits securely over the riser tube.

Silicone grease (#13691) or other food grade lubricant may be applied to the O-ring to ease installation of the riser

tube. DO NOT use petroleum based lubricants as they will cause swelling of O-ring seals.

• The softener or filter is now charged with softening resin.

• It is recommended that the softener or filter tank now be completely filled with water (SLOWLY) to soak the resin

or filtration media before startup. This will allow the media to absorb water as well as help displace any trapped

air. This will reduce the chance of backwashing resin or filter media out of the tank during the initial backwash on

startup.

2. Outside faucets used to water lawns and gardens should not supply softened water. A new water line is often

required to be connected to supply hard water to the inlet of the water softener and to the outside faucets. Cut the

water line between where it enters the house and before any lines that branch off to feed the hot water heater or

other fixtures in the house and as near the desired location of the water softener as possible. Install a tee fitting

on the feed end of the cut pipe, and an elbow fitting on the other end. Install piping from the tee to the inlet of the

water softener and from the elbow to the outlet of the softener. To sever the water lines which branch off to feed

any outside faucets, cut the branch lines approximately two inches from the fitting on the main water line. Install an

elbow on the end of the pipe nearest the outside faucet and a cap on the end connected to the existing water line.

Install piping from the tee installed on the inlet line to the water softener to the elbow installed on the pipe to the

outside faucet. Following this procedure will result in all lines in the house, with the exception of the outside faucets,

but including the water heater and therefore the hot water lines, being supplied with soft water.

3. Familiarize yourself with the location of the inlet, outlet and drain on the control valve. Be very careful not to get the

controls wet.

Figure 1

Electrical Panel

Ground Strap

Poly Pipe

Ground

From

Panel

Poly Pipe

Softener

c/w Plastic Bypass

Copper Pipe

Water Meter

Figure 2

Outside Water Line For Outside & 3rd Tap Comes From Meter

Filtered Water Line in Home

Unfiltered Water Bypass

Loop Cut & Capped

Ground Strap Required

Because of Break in Continuity