Time Brine Refill and Meter Setting Procedure

4. Set meter wheel at approximately 2530 gallons. Lift the inner dial of the meter program wheel so that you can

rotate it freely. Position the white dot opposite the 2530 gallon setting.

NOTE:

There is a slight delay between the time the meter zeros out and the cycle starts. Units using the:

1/15 RPM motor, 82 minute Regeneration Time has a 9 minute delay

1/30 RPM motor, 180 minute Regeneration Time has an 18 minute delay.

.

NOTE:

This delay period is not critical on residential equipment. However, take this factor into consideration.

for commercial applications by subtracting continuous flows for 9 minutes or 18 minutes from water available.

5. Insert meter cable into meter.
6. Check bypass.
7. Plug in unit.