Clear-Com HX System Frames User Manual

Page 66

Advertising
background image



Figure 24: Power supplies: Front panel lights and controls

The front panel alarm lights, power supply lights, and reset button are shown in Figure 24.

An alarm source triggers the

red

main alarm light and also one of the additional six

red

alarm lights, allowing the system operator to identify or correct alarm conditions before they
affect the operation of the matrix.

Each of the four

green

power supply lights stays on continuously to show that the power

supplies are receiving sufficient AC current. When one of these lights switches off, the power
supplies must be replaced or repaired.

Under normal operating conditions, the

red

front-panel alarm lights stay off, while the

green

power supply lights stay on continuously.

Note:

The XP type power supplies (part 740101Z) may need to be adjusted if E-QUE, E-FIB,
IVC-32 or LMC-64 interface cards are installed. For more information, see the
Eclipse HX Upgrade Guide.

Power-One power supply units (part 720379Z) should not be adjusted.

Euro Cassette
Power Supply 1

Euro Cassette
Power Supply 2

Euro Cassette
Alarm lights

Alarm reset
button

Power supply lights
(

green

when lit):

+12 V light
+5 V light
+3.3 V light
-12 V light

Alarm lights
(

red

when lit):

Main alarm light
External alarm light
Temp alarm light
Fan-fail alarm light
PSU1 fail light
PSU2 fail light
Fan-on alarm light

66

Eclipse HX-Median User Guide

Advertising
This manual is related to the following products: