Hach-Lange HQ411D Basic User Manual User Manual

Page 3

Advertising
background image

Table of contents

Specifications

on page 3

General information

on page 3

Installation

on page 5

User interface and navigation

on page 7

Startup

on page 9

Standard operation

on page 10

Data management

on page 11

Maintenance

on page 13

Troubleshooting

on page 14

Specifications

Specifications are subject to change without notice.

Specification

Details

Dimensions

17.48 x 8.59 x 23.5 cm (6.88 x 3.38 x 9.25 in.)

Weight

750 g (1.65 lb) without batteries

Meter enclosure

IP54 with battery cover in place (resistant to intrusion
of dust and water spray)

Power requirements
(internal)

AA Alkaline or rechargeable Nickel Metal Hydride
(NiMH) batteries (4); battery life: up to 200 hours

Power requirements
(external)

Class III, external power adapter: 100–240 VAC,
50/60 Hz input; 4.5 to 7.5 VDC (7 VA) output

Meter protection class

Class I

Storage temperature

–20 to +60 °C (–4 to +140 °F)

Operating temperature

5 to 45 °C (41 to 113 °F)

Operating humidity

90% (non-condensing)

5-pin input connector

M12 connector for IntelliCAL

probes

Data memory (internal)

500 results

Data storage

Automatic in Press to Read mode and Interval Mode.
Manual in Continuous Read Mode.

Specification

Details

Data export

USB connection to PC or USB storage device
(limited to the storage device capacity). Transfer
entire data log or as readings are taken.

Connections

Integrated USB type A (for USB flash memory
device, printer, keyboard) and Integrated USB type B
(for PC)

Temperature correction

Off, automatic and manual (parameter dependent)

Measurement display
lock

Continuous measurement, Interval or Press to Read
mode. Averaging function for LDO probes.

Keyboard

External PC keyboard connector with USB/DC
adapter

General information

Revised editions are found on the manufacturer’s website.

Safety information

N O T I C E

The manufacturer is not responsible for any damages due to misapplication or
misuse of this product including, without limitation, direct, incidental and
consequential damages, and disclaims such damages to the full extent permitted
under applicable law. The user is solely responsible to identify critical application
risks and install appropriate mechanisms to protect processes during a possible
equipment malfunction.

Please read this entire manual before unpacking, setting up or operating
this equipment. Pay attention to all danger and caution statements.
Failure to do so could result in serious injury to the operator or damage
to the equipment.
Make sure that the protection provided by this equipment is not impaired.
Do not use or install this equipment in any manner other than that
specified in this manual.

English 3

Advertising