Make on/off module a controller, Groups, Scenes – INSTEON On/Off Module - 2633-422 (France), 2633-432 (Germany), 2633-442 (UK), 2633-522 (AUS/NZ) Manual User Manual

Page 6

Advertising
background image

Page 6 of 14 Rev: 1/21/2014 7:47 AM

Make On/Off Module a Controller

1) Press and hold On/Off Module set button until it beeps

On/Off Module LED will start blinking green
You will have four minutes to complete the next steps before linking mode times out

2) Adjust responder to desired state

3) Press and hold responder set button until it double-beeps

On/Off Module will double-beep and its LED will stop blinking

1

4) Test link by tapping or pressing and holding On/Off Module paddle to turn on/off or brighten/dim

Responder will respond appropriately

Note:

-

The link just created is one way. See

Make On/Off Module a Responder

or

Groups

to add

another link to keep the two products in sync.

-

If you wish the load to be off when link is activated—such as for an “all off” scene—turn off the
load in step #2.

Groups

Devices in a group share all the same settings (e.g., on-level, ramp rate). This keeps all group members
synchronized. Every device in a group is both a controller of, and responder to, all the other devices. The
most common example of a group is a 3-way lighting circuit (2 switches). For simplicity, we will assume
that the desired group level is on.


The following steps will create a virtual 3-way circuit including device “A” and device “B”:

1)

Turn A and B on

2)

Press and hold A set button until it beeps

A status LED will start blinking green

3)

Press and hold B set button until it double-beeps

A will double-beep and its LED will stop blinking

4)

Press and hold B set button until it beeps

B LED will start blinking green

5)

Press and hold A set button until it double-beeps

B will double-beep and its LED will stop blinking

6)

Test by turning load on and off from A and then B

The load(s) and both A and B LEDs will remain in synch

Scenes

Devices in a scene can each have different settings. This provides for advanced scene creation. Software
is recommended for scene management.

Example of a scene with 1 controller and On/Off Module as a member:

1) Press and hold controller set button until it beeps

Controller LED will start blinking green

2) Tap controller set button

Controller LED will start double-blinking green

1

If either controller or responder LED continues blinking, the addition failed. Tap device’s set button until LED stops blinking and try linking again.

Advertising