Linking in-linelinc relay as an insteon controller, Advanced features, Creating insteon scenes – INSTEON In-LineLinc Relay (2475S2) Manual User Manual

Page 8: Linking in-linelinc relay to multiple responders

Advertising
background image

Page 8 of 14 Rev: 1/21/2014 7:57 AM

Linking In-LineLinc Relay as an INSTEON Controller

With the Sense wire connected, you can control INSTEON responders based on the state of In-LineLinc’s
load—it will automatically activate the connected load and any other linked devices when it detects 120V
(such as when a motion detector is tripped), then turn them off when it no longer senses 120V. Be sure to
link In-LineLinc to responders before you finish installing it in its junction box. To link multiple responders
at once, see Linking In-LineLinc Relay to Multiple Responders.

Most responders use the procedure below:
1) Press and hold In-LineLinc’s Set button until it beeps.

In-LineLinc’s status LED will start blinking.

You will have 4 minutes to complete the next step before linking mode times out.

2) Set the responder to the state you want when activated from In-LineLinc.
3) Press and hold the responder’s Set button for about 3 seconds.

In-LineLinc will double-beep and its status LED will stop blinking and turn on solid.

4) Confirm that linking was successful by tapping the In-LineLinc’s On and Off buttons.

The responder will respond appropriately.

Unlinking In-LineLinc Relay as an INSTEON Controller

If you are no longer going to use an In-LineLinc Relay that is controlling one or more INSTEON
responders, it is important that you unlink all of them from In-LineLinc. Otherwise, the controller will retry
commands and cause network delays.

Most responders use the unlinking procedure below:
1) Press and hold In-LineLinc’s Set button until it beeps.

In-LineLinc’s status LED will start blinking.

2) Press and hold In-LineLinc’s Set button until it beeps again.

Status LED will continue blinking.

You will have 4 minutes to complete the next step before unlinking mode times out.

3) Press and hold responder’s Set button about 3 seconds.

In-LineLinc will double-beep and its status LED will stop blinking.

4) Confirm that unlinking was successful by tapping In-LineLinc’s On and Off buttons.

The load responder will not respond.

Advanced Features

Creating INSTEON Scenes

INSTEON scenes let you activate dramatic room ambiences with multiple lights and appliances. For
example, you can set all the lights in a scene to dim to 50% or turn certain lights on while turning others
off, all with the tap of a button on a controller.

INSTEON scenes are very easy to set up: just link more than one responder to the same On/Off or scene
button on a controller. Then, when you press any of the linked buttons on the controller, all of the
INSTEON devices linked in the scene will respond as a group.

To set up an INSTEON scene, you can individually link each device to a controller. Or save time and
create multiple links at once by following the steps below.

Linking In-LineLinc Relay to Multiple Responders

1) Adjust each responder you want In-LineLinc Relay to control to the desired state.
2) Press and hold In-LineLinc’s Set button until it beeps.