Installation – INSTEON Micro Open/Close - 2444-222 (US), 2444-422 (EU), 2444-522 (AUS/NZ) Manual User Manual

Page 6

Advertising
background image

Page 6 of 21

2444-222/2444-422/2444-522 - Rev: 2/24/2014 9:10 AM

Installation

1)

Write down the INSTEON ID found on the back of the unit (XX.XX.XX)

2)

Turn off breaker/fuse and verify that the power is off

3)

Disconnect wires from existing switch, fixture or outlet and prep all wires to
be connected to Micro module, with 3/16” (5mm) of bare wire on the ends

4)

Connect wires per diagram which corresponds to your installation

Note: sense lines carry very low current (~0.35mA 240V, ~0.17mA for 120V)

5)

After ensuring wires are firmly connected and that there is no exposed wire, turn on breaker/fuse

After a few seconds, Micro module LED will turn green

6)

Test by tapping Micro module up/down buttons

Motor will respond accordingly
Micro Module LED will turn green when motor is moving up/open and stay green until the down button is pressed
Micro Module LED will turn red when motor is moving down/closed and stay red until the up button is pressed

7)

If installing a single momentary or dual momentary switch
a) Press and hold set button until it beeps

LED will start blinking green

b) Press and hold set button until it beeps a second time

LED will start blinking red

c) Press and hold set button until it beeps a third time

LED will start blinking green

d) Perform the step that applies

For single momentary: slowly tap set button four times

LED will continue blinking green

For dual momentary: slowly tap set button five times

LED will start double-blinking green

To switch back to latching: slowly tap set button six times

LED will start blinking green

e) Once the mode is selected, press and hold set button until it double-beeps

LED will stop blinking and turn green if motor is up/open or red if motor is down/closed

Antenna

Down

Up

Down

Up

Down

Up

Down

Up

Advertising