Test Button Descriptions

Note: Unit under test = last responder linked
*This feature only works with INSTEON devices shipped after March 2012 (i2CS).

**Only applies to devices shipped prior to March 2012.

Directions

Note:

-

This manual presumes user has a moderate to expert understanding of INSTEON and INSTEON products.

-

Diagnostic Keypad only contains a single link. When you are finished testing a device, be sure to UNLINK it from
Diagnostic Keypad before linking your next device. If you link a second device without unlinking the first, it will
overwrite the existing link and the first device will still contain a half-link to Diagnostic Keypad. The first device
will have to be factory reset to remove the half-link.

-

UNLINK device upon completion of test. Otherwise, the device under test will retain a responder link.

ON/OFF

TOGGLE

Sends on/off broadcast

without confirmations to

unit under test

BEEP

Sends a beep message
to unit under test (some

responders will still

beep even after

unlinking from

Diagnostic Keypad)**

REPORT*

Monitors the quality of

control signals from the

device under test and

beeps upon receipt of

success reports

TRAFFIC

Blink on valid traffic

and long-beep upon

collisions/noise

DISTANCE

Sends alternating fast-

ons and fast-offs to unit

under test, beeping

upon receipt

LOCK/

UNLOCK*

Disable local setup of

unit under test

RELINK*

Relinks to last unit

under test

UNLINK*

Unlinks the unit under

test