Advanced 2-stage heating or cooling systems, Factory reset – INSTEON Wireless Thermostat with Humidity (2441ZTH) Manual User Manual

Page 20

Advertising
background image

Page 20 of 27 Rev: 1/21/2014 8:36 AM

2) Press Program to exit calibration mode

Advanced 2-Stage Heating or Cooling Systems

INSTEON Wireless Thermostat does not have the ability to operate first or second stages of Heat or Cool
directly but can instruct INSTEON Thermostat to operate the HVAC. First and second stage of Heat or
Cool engages under the following conditions when INSTEON Thermostat is connected to the HVAC:

INSTEON Thermostat setpoint is set at 5

°(F or C)

or more below ambient in Cool mode and 5

°

(F

or C) or more above ambient in Heat mode

-

Heat mode setpoint is 80°, ambient is 72° = first and second stage engaged

-

Cool mode setpoint is 78°, ambient is 84° = first and second stage engaged

INSTEON Thermostat has been active in Heat or Cool for longer than 10 minutes and did not
reach setpoint

-

Heat mode ran for 10 minutes and did not reach setpoint = second stage engaged

-

Cool mode ran for 10 minutes and did not reach setpoint = second stage engaged

Note: It is possible for INSTEON Thermostat to occasionally engage and disengage second stage during
a single heating or cooling cycle as variables are met.

Factory Reset

If you want to reset INSTEON Wireless Thermostat to its factory default settings, follow instructions
below.

Note: If you choose to reset INSTEON Wireless Thermostat to its factory default settings, it is important
that you remove scene memberships from all controllers. Otherwise, controllers will retry commands
repetitively, creating network delays. Follow the instructions in
Removing INSTEON Wireless Thermostat
as an INSTEON Responder above for each scene controller of which INSTEON Wireless Thermostat is a
member.

Factory reset changes:

• INSTEON is reset (all scene memberships are removed)

• Day/time is changed to 12:00PM

• Programming times, temperatures and other settings are reset to their default values

Factory reset does not change:

• Temperature offset

• Humidity offset


Factory Reset
1) Open INSTEON Wireless Thermostat and remove a battery
2) Wait 10 seconds
3) While pressing and holding the Set button, reinsert the removed battery. Do not let go of Set button.

Device will blink all segments and emit a long beep for about 10 seconds

Advertising