Base installation, Above ground, base installation, Warning – King Technology POOL FROG Model 6100 User Manual

Page 15

Advertising
background image

15

HOSE

CLAMP


HOSE

ADAPTER

HOSE

CLAMP


HOSE

ADAPTER

TO POOL

1 1/2" OR 1 1/4"

FLEX HOSE

1 1/2"

X

1 1/2"

X

1 1/4"

HOSE ADAPTER

HOSE

CLAMP

FILTER &

PUMP

TOOLS NEEDED

Screwdriver

Pipe Wrench

Materials Needed

Pipe Thread
Tape
or Sealant

One 6” X 1 1/2” TBE
PVC Nipple

Two Sections
of 1 1/2” Flex Hose (one
provided with filter)

Two
Hose Clamps

Recommended

Corrosion Resistant
Check Valve

10 X 1 1/4” Phillips
Pan Head Screws with
Washers

Option
1 1/2” Male Adapter
(slip x MPT)

or

2” Female Adapter
(slip x FPT)

When installing with hard
PVC pipe, use either a
female adapter on the
outside port threads or
a male adapter on the
inside port threads.

Apply pipe thread tape or
sealant to the threaded end of
both hose adapters.

1.

The POOL FROG® Cycler should always be
installed between the filter and pool (or between
heater and pool if applicable).

Above Ground, Base Installation

Screw adapters into each end of POOL
FROG® Cycler. Hand tighten. Finish
tightening by turning 1 to 2 revolutions
with wrench. DO NOT OVER TIGHTEN.

2.

Attach the filter section of flex hose to one hose adapter
and the return section of flex hose to the other hose
adapter with clamps and tighten with screwdriver. Bi-flow
valve design allows water flow in either direction.

3.

If using a POOL FROG® Bac Pac installing a
corrosion resistant check valve is recommended.

4.

For better stability, POOL
FROG® Cycler may be mounted
on a base using Phillips pan
head screws. One in front and
two in back.

5.

TO POOL

PUMP

FILTER

• Never install POOL FROG before
the heater.
• Any additional sanitizing equipment
that is installed with FROG must be
installed after FROG (never before) on
the return line to the pool.

WARNING

Advertising