N o t e, Connecting to power, Resistance of copper wire [at 20 ℃ (68˚f) – KT&C KPC-ZA180NH User Manual

Page 11

Advertising
background image

6 . I n s t a l l a t i o n

• Connect the power once the installation is complete.

• When connecting to the power source, make sure the polarity of the power adapter
is correct.
• Use a DC12V/500mA power source for the camera.

N O T E

Connecting to Power

Connect the power cable to the camera's power in as shown in the figure below

• As the voltage drop according to the length of the cable in the above table, a
camera may malfunction if there is an excessively long cable run.

• Voltage drops in the above table are variable according to types of cable
manufacturer.

Resistance of copper wire [at 20

(68˚F)]

Copper wire size

(AWG)

#24

(0.22

)

#22

(0.33

)

#20

(0.52

)

#18

(0.83

)

Resistance(Ω/m)

0.078

0.050

0.030

0.018

Voltage Drop(V/m)

0.028

0.018

0.011

0.006

1 2

1 3

Advertising