INSTRUCTION NUMBER: AO-70136 BA

2 of 9


1.0 GENERAL

INFORMATION



1.1 RECEIVING AND UNPACKING

Handle and unpack the equipment carefully.

Immediately upon arrival, check the shipment against

the packing list. Any damage should be reported

immediately to the carrier and to the nearest CMC

representative.

Equipment that will not be installed immediately

should be stored in a clean, dry location. Precautions

should be taken to prevent moisture, dust and dirt

from accumulating in storage and installation areas


1.2 PRECAUTIONS

1.2.1 Shipping - It is recommended that the sensing

roll be removed when the machine is shipped with the

transducers mounted. The shock and vibration

transmitted to the transducers by the sensing roll

during transporting can damage them.


1.2.2 Roll Balance - The sensing roll should be
balanced to prevent forces caused by imbalance.
These forces cause a noise signal to be superimposed
on the tension signal. The centrifugal force (F) caused
by imbalance can be calculated using the equation
below.

F = 28.6 x 10

-6

x W x R x (RPM)

2

Lbs.

W = Weight of roll in pounds

R = Displacement of mass of roll from the

axis of rotation in inches

RPM = Revolution per minute

It is recommended that the force (F) be less than 5%

of the resultant web force at the maximum web speed

for most applications.


1.2.3 Critical Roll Speed - Even with a balanced roll, a
vibration can be set up in a stationary shaft. If this
vibration (in cycles per minute) occurs at the
harmonic frequency of the shaft, the transducers can
be damaged. To determine the critical roll speed, use
the following formula:




Critical roll = 4.8 x 10

6

x Shaft O.D.

speed in RPM

(Shaft Length)

2

Dimensions are in inches.

To assure that this problem is avoided, the critical roll

speed should at least be 20% above the roll speed

attained at maximum web speed.

1.2.4 Overloading - Repetitive overloading above the

maximum working force or severe overloading should

be avoided because it will damage the transducers.


1.3 SPECIFICATIONS


Gage Resistance

- End to end resistance 440-480

Ohms


Gage Factor

- 100 nominal


Excitation Voltage

-10 VDC or VAC (RMS)

maximum


Output Signal
at Rated MWF

- 100 mV nominal per

Transducer (1/2 bridge)

200 mV nominal per
Transducer pair (full bridge)


Output Impedance

- Approximately 880 Ohms for

UPB2 and UPB3

Approximately 120 for UPB 1



Required Input
Impedance of
Tension Amplifier

- 5K ohms per Transducer (1/2

bridge)


Maximum Voltage,
Gage to Beam or
Base (Ground)

- 50 VDC


Operating
Temperature Range - 0

F to +200

F


Compliant