3.0 ELECTRICAL

CONNECTION




Figure 8


Refer to the installation wiring diagrams supplied
with the Cleveland-Kidder tension indicator or
controller for making the transducer connections.
Make certain that the cables do not interfere with
the web path and that they are away from gearing
or other moving parts.

Many of the Cleveland-Kidder indicators and
controllers use only half bridge transducer inputs
and then sum the two transducer signals internally.
See the applicable installation wiring diagrams for
the tension indicator or controller.


3.1

MATING CONNECTORS FOR
TRANSDUCERS


USE CMC P/N

Mating Straight Connector,
Boot and Clamp Kit

MO-09854

Mating 90

Angle Connector,

Boot and Clamp Kit

MO-09855

These are not sealed for washdown duty. For

washdown duty mating connector consult CMC.

3.2 INTRINSICALLY

SAFE

TRANSDUCERS

These transducers are intrinsically safe only when

they are part of a complete intrinsically safe

system using the TIX-1 tension indicator or wired

per CMC control drawings.

Barrier block assemblies and/or the individual

barrier blocks may be purchased from CMC. Please

contact CMC for part numbers and pricing.

4.0 TEMPERATURE

COMPENSATION

The transducers are supplied with a temperature

compensation network (except size 1 which don’t

require it) which is in series with the output signal

lead. The compensation circuit is designed to be

used with a tension amplifier which has an input

impedance of 10K Ohms when a pair of transducers

connected as a full bridge is used. If only one

transducer is used, the tension amplifier impedance

should be 5K Ohms. If other than the input

impedances given above are used, drift will occur

in the tension amplifier output when the transducer

temperature changes.

5.0 SINGLE

TRANSDUCER

OPERATION

For those applications where only one transducer is

required, a dummy circuit may or may not be

required depending upon the input circuit of the

tension amplifier. Consult the factory for this

information. The dummy circuit consisting of two

resistors is substituted in place of the second

transducer. The resistors should have a resistance

value between 100 and 150 Ohms and should be

matched to within 1%. Dummy circuits are

available from the factory for connecting to tension

indicators or controllers.

6.0 TROUBLESHOOTING

6.1

EXCESSIVE OUTPUT SIGNAL

WITH NO LOAD



There may be a high degree of misalignment of the
transducers causing a severe pre-load.

Or

The sensing guide roll assembly may be

excessively heavy. The sensing guide roll should

BLK

WHT

SHIELD

BLK

WHT

RED

EXCITATION

VOLTAGE

OUTPUT

SIGNAL

(-)

(-)

(+)

(+)

B

C

A

TENSION GAGE

COMPRESSION GAGE

TEMP. COMPENSATION

NETWORK

NO. 1

TRANSDUCER

COMPRESSION GAGE

TEMP. COMPENSATION

NETWORK

C

A

TENSION GAGE

B

NO. 2

TRANSDUCER

WIRING DIAGRAM FOR TRANSDUCERS

RED