Figure 2 – Cleveland Motion Controls Classic UPB Transducer Load Cell REV BA User Manual

Page 3

Advertising
background image


INSTRUCTION NUMBER: AO-70136 BA

3of 9

F

G

J

E

H

D

W

LOAD CELL

PILLOW BLOCK

MOUNTING PLATE

A

B

M

N

K

C

L

1.4 DESCRIPTION

The Cleveland-Kidder Washdown Duty UPB

transducers utilize a sensing twin beam to which

semiconductor strain gages are bonded. With these

high output signal gages a very small force on the

sensing beam will be shown as a change in the tension

signal.

The type UPB transducers are for use with shafts that

are mounted in Pillow Block Bearings. See Figure 1.

For mounting dimensions see Figure 2.

Figure 1

Dimensions in Inches*

Size

No.

A B C D

E F(Max.)

G H J

(Max.) K L

M N W

Maximum Working Force (lb.)

1

1.5 0.55 5.8

1.5

5/16 (4)

5.8

1.6

1.95

½ (2)

1.40

6.5

1.3

2.2 2.2

25, 50, 100, 250, 500, 1000

2

3

0.80 10.0

3.0

½ (4)

10.0

3.0

2.5

¾ (4)

1.71 11.0

3.3 3.95 4.0 1000, 2500, 5000, 10000, 20000

3

4.5 1.63 15.0

4.5

1 (4)

15.6

5.0

4.2

1-1/8 (4) 2.80 17.0

4.8

5.2 6.5

10000, 20000, 30000

Dimensions in Millimeters*

Size

No.

A B C D

E F(Max.)

G H J

(Max.) K L

M N W

Maximum Working Force (N.)**

1

38

14 147.5 38

M8

147

40.5

49.5

M12 (2) 35.5 165

33

56

56 110, 225, 450, 1100, 2250, 4500

2

76

20

254

76

M12

254

76

63.5

M20 (4) 43.5 279.5 84

100 101.5 4500, 11000, 22000, 45000, 9000

3 114 41.5 381 114 M24 396 127 106.5 M30

(4) 71 432 122 132 165

45000,

9000,

13500

*Allow 2.5 inches (64 mm) clearance for connector
**Approximate rating in Newtons

Figure 2

Pillow Block Bearing

Washdown UPB Transducer