6 emc – Cleveland Motion Controls DIN Rail Amplifier MWI-13262 Ultra Series Non-Isolated REV BA User Manual

Page 7

Advertising
background image

MAN-13262

R

EV

BA

DIN

R

AIL

A

MPLIFIER

,

MWI-13262

U

LTRA

1.4 E

NVIRONMENTAL

R

EQUIREMENTS

Requirement

Description

Enclosure

IP20
NEMA 1

Operating temperature

0 to 55 degrees C
32 to 132 degrees F

Humidity

Non-condensing
85% at 55 degrees C
85% at 132 degrees F

Altitude

1000 meters
3300 feet

Atmosphere Non-flammable, non-corrosive and dust free

Storage temperature range

-25 to 80 degrees C
-13 to 176 degrees F

Transport temperature range

-25 to 80 degrees C
-13 to 176 degrees F

1.5 O

PERATING

C

ONDITIONS

Condition

Ultra Series DIN Rail amplifier

Installation category

Category III

Pollution Pollution

Degree

2

Input supply

Earth (Ground) referenced

Protection Enclosure

mounted

1.6 EMC

T

ECHNICAL

R

ATINGS

Port

Phenomenon

Test Standard

Level

Test Standard

Enclosure

ESD

EN 61000-4-2:

8KV AD, 1KV CD

EN 61326:1997

Enclosure

RF Field

EN 61000-4-3

10V/m,1 Khz AM

EN 61326:1997

Transducer Leads

Fast Transient
Burst

EN 61000-4-4

1kV

EN 61326:1997

Output Leads

Fast Transient
Burst

EN 61000-4-4

1kV

EN 61326:1997

Transducer Leads

Conducted
Immunity

EN 61000-4-6

3V/m

EN 61326:1997

Output Leads

Conducted
Immunity

EN 61000-4-6

3V/m

EN 61326:1997

AC Power Line

Surge

EN 61000-4-5

+/-2KV L to PE
+/-1KV L to L

EN 61326:1997

AC Power Line

Voltage Dips

EN 61000-4-11

+/-0.5 Cycle
100%

EN 61326:1997

1.7 E

MISSION SPECIFICATIONS

Port

Phenomenon

Test Standard

Level

Generic Standard

Enclosure Radiated

EN

61326:

1997

Class A

EN 61326:1997


The levels of performance indicated are achieved when the Ultra Series DIN Rail Amplifier is
installed by using the instructions and specifications outlined in this document.

P

AGE

7

OF

26

Advertising