Etup and, Onfiguration – Cleveland Motion Controls DIN Rail Amplifier MWI-13262 Ultra Series Non-Isolated REV BA User Manual

Page 9

Advertising
background image

MAN-13262

R

EV

BA

DIN

R

AIL

A

MPLIFIER

,

MWI-13262

U

LTRA

2 S

ETUP AND

C

ONFIGURATION

2.1 L

OAD

C

ELL

(T

RANSDUCER

)

T

ERMINALS

Terminal

Function

Description

Notes

EXC RET

Supply return for bridge
excitation

Zero voltage terminal for
LCH and RCH transducers

COMMON

+V EXC

Bridge excitation source for
LCH and RCH transducers

5.0 Volt or 10.0 Volt supply terminal,

max. load 100 mA

-IN LCH

Load cell signal from LCH
transducer

Low going output from LCH
transducer

10K ohm line-to-line

+IN LCH

Load cell signal from LCH
transducer

High going output from LCH
transducer

-IN RCH

Load cell signal from RCH
transducer

LOW going output from RCH
transducer

10K ohm line-to-line

+IN RCH

Load cell signal from RCH
transducer

High going output from RCH
transducer

OPEN (N.C.)

NO CONNECTION

Make no connection

SHLD DRN

Cable shield
drain terminal

Cable Shield for LCH and RCH
transducer cables

Connect only at amplifier


Transducers (load cells) use strain gages which have limited insulation levels to ground (earth).
This requires that the COM terminals be connected to ground (earth) to prevent damage to the
transducers (load cells).

2.2 P

OWER

S

UPPLY

T

ERMINALS

Output

Terminal

Function

Description

Notes

J2-1

24V RET

Power Supply

Power supply return

Must not exceed 50 volts
from P.E.

J2-2

+24 VDC

Power Supply

Positive supply source

+20 to +28 VDC
@ 160 mA max


A fuse with a rating of 0.38A must be used in the 24 VDC supply lead to limit potential
damage to the amplifier in the event of circuit malfunction.

2.3 O

UTPUT

T

ERMINALS

Output

Terminal

Function

Description

Notes

J2-3

COMMON

Output signal return


Common for +/- 10V and
+/-2V output

J2-4

+/- 10V OUT

Voltage Output signal

Undamped bi-polar
tension signal

max. load 2 mA

J2-5

mA MTR RET

mA meter signal

Used for current format meter
return

Current through 1 mA
meter returns here

J2-6 METER

OUT Output

signal

Damped bi-polar tension
signal

Switchable 2.0 V F.S.
or 1 mA F.S.

J2-7 4-20mA

OUT

Current loop Output
signal

Undamped tension signal,
current loop source

Internal Loop supply

J2-8

4-20mA RET

Output current signal

Current return for
4-20 mA loop

At -15 VDC with respect to
common

P