Xc 0.8, Ready to use, Error lamp – CTEK XC 0.8 User Manual

Page 2: Technical specifications, Fully charged

Advertising
background image

4 • EN

BaTTErY SiZE (ah)

TiME TO 80% chargED

2ah

2h

8ah

8h

20ah

20h

60ah

60h

rEaDY TO USE

The table shows the estimated time for empty battery to 80% charge

ErrOr LaMP

if the error lamp is lit, check the following:

— Is the chargers positive lead connected to the

batterys positive pole?

— Connect the charger according to page 6.

TEchnicaL SPEciFicaTiOnS

charger model

XC 0.8

Model number

1054

rated Voltage ac

220–240VAC, 50–60Hz

charging voltage

7.2V

Start voltage

3.7V

charging current

0.8A max

current, mains

0.2A rms (at full charging current)

Back current drain*

<1Ah/month

ripple**

<4%

ambient

temperature

-20°C to +50°C, output power is reduced

automatically at high temperatures

charger type

4-step, fully automatic charging cycle

Battery types

All types of 6V lead-acid batteries

(WET, MF, Ca/Ca, AGM and GEL)

Battery capacity

1.2–100Ah

Dimensions

142 x 51 x 36mm (L x W x H)

insulation class

IP65

Weight

0.3kg

*) Back current drain is the current that drains the battery if the charger is not connected

to the mains. CTEK chargers has a very low back current.

**) The quality of the charging voltage and charging current is very important. A high

current ripple heats up the battery which has an aging effect on the positive electrode.

High voltage ripple could harm other equipment that is connected to the battery. CTEK

battery chargers produce very clean voltage and current with low ripple.

6V/0.8A