Charging program, Limited warranty – CTEK XC 0.8 User Manual

Page 3

Advertising
background image

EN

EN • 5

1

VOLTAGE (V)

CURRENT (A)

PULSE

DESULPHATION

BULK

ABSORPTION

Increasing voltage

to 7.2V

0.8A

1

7.2V

7.2V

Declining current

6.4V‒7.2V

0.8‒0.4A

2

3

4

charging PrOgraM

XC 0.8 is equipped with a multi purpose charging program. XC 0.8 charges all batteries 1.2–100Ah

in the temperature range of -20˚ to +50˚C (-4˚F to +122˚F).

CTEK SWEDEN AB, issues this limited warranty to

the original purchaser of this product. This limited

warranty is not transferable. The warranty applies

to manufacturing faults and material defects for

5 years from the date of purchase. The customer

must return the product together with the receipt of

purchase to the point of purchase. This warranty

is void if the battery charger has been opened,

handled carelessly or repaired by anyone other

than CTEK SWEDEN AB or its authorised repre-

sentatives. CTEK SWEDEN AB makes no war-

ranty other than this limited warranty and is not

liable for any costs other than those mentioned

above, i.e. no consequential damages. Moreover,

CTEK SWEDEN AB is not obligated to any war-

ranty other than this warranty.

LiMiTED WarranTY

STEP 1 DESULPhaTiOn

Detects sulphated batteries. Pulsing cur-

rent and voltage, removes sulphate from

the lead plates of the battery restoring

the battery capacity.
STEP 2 BULK

Charging with maximum current until

approximately 80% battery capacity.
STEP 3 aBSOrPTiOn

Charging with declining current to maxi-

mize up to 100% battery capacity.
STEP 4 PULSE

Maintaining the battery at 95–100%

capacity. The charger monitors the

battery voltage and gives a pulse when

necessary to keep the battery fully

charged.

Advertising