BATTERY SIZE (Ah)

TIME TO 80% CHARGEd

2Ah

2h

8Ah

8h

20Ah

4h

60Ah

12h

110Ah

26h

REAdY TO USE

The table shows the estimated time for empty battery to 80% charge

CHARGING PROGRAMS

Settings are made by pressing the MODE-button. After about two seconds the charger

activates the selected program. The selected program will be restarted next time the

charger is connected.

The table explains the different Charging Programs:

Program

Battery

Size (Ah)

Explanation

Temp range

1.2–14Ah

Small battery program

14.4V/0.8A

Use for smaller batteries.

-20°C–+50°C

(-4ºF–122ºF)

14–160Ah

Normal battery program

14.4V/5A

Use for WET batteries, Ca/Ca,

MF, GEL batteries and many

AGM batteries.

+5°C–+50°C

(41ºF–122ºF)

14–160Ah

Cold weather program

14.7V/5A

Use for charging at low tempera-

tures and for power AGM batter-

ies like Optima and Odyssey.

-20°C–+5°C

(-4ºF–41ºF)

RECOND

14–160Ah

Recond program 15.8V/1.5A

Use to return energy to the empty

WET and Ca/Ca batteries.

Recond your battery once per

year and after deep discharge to

maximise lifetime and capacity.

The Recond program adds

STEP 6 to the

normal battery

program. Frequent use of the

Recond program may cause

water loss in the batteries and

reduce service life of electronics.

Contact your vehicle and battery

supplier for advice.

-20°C–+50°C

(-4ºF–122ºF)

ERROR LAMP

If the error lamp is lit, check the following:

1. Is the chargers positive lead connected to the battery´s

positive pole?

2. Is the charger connected to a 12V battery?
3. Has charging been interrupted in STEP 1, 2 or 5?

Restart the charger by pressing the MODE-button. If charging is still

being interrupted, the battery...

STEP 1: ...is seriously sulphated and may need to be replaced.

STEP 2: ...can not accept charge and may need to be replaced.

STEP 5: ...can not keep charge and may need to be replaced.

POWER LAMP

If the power lamp is lit with a:

1. STEAdY LIGHT

The mains cable is connected to the wall socket.

2. FLASHING LIGHT:

The charger has entered the energy save mode. This happens if the

charger isn´t connected to the battery in 2 minutes.