Comfort connect, Technical specifications, Connect and disconnect the charger to a battery – CTEK MXS 5.0 v1 User Manual

Page 4

Advertising
background image

6 • EN

TECHNICAL SPECIFICATIONS

Charger model

MXS 5.0

Model number

1049

Rated Voltage AC

220–240VAC, 50–60Hz

Charging voltage

14.4V, 14.7V,

15.8V

Min battery voltage 2.0V
Charging current

5A max

Current, mains

0.65A rms (at full charging current)

Back current drain*

<1Ah/month

Ripple**

<4%

Ambient

temperature

-20°C to +50°C, output power is reduced

automatically at high temperatures

Charger type

Eight step, fully automatic charging cycle

Battery types

All types of 12V lead-acid batteries (WET, MF, Ca/Ca, AGM and

GEL)

Battery capacity

1.2―110Ah up to 160Ah for maintenance

dimensions

168 x 65 x 38mm (L x W x H)

Insulation class

IP65

Weight

0.6kg

*) Back current drain is the current that drains the battery if the charger is not connected to

the mains. CTEK chargers has a very low back current.

**) The quality of the charging voltage and charging current is very important. A high cur-

rent ripple heats up the battery which has an aging effect on the positive electrode. High

voltage ripple could harm other equipment that is connected to the battery. CTEK battery

chargers produce very clean voltage and current with low ripple.

+

+

Comfort

Connect

MODE

RECOND

12V/5A

MXS 5.0

CONNECT ANd dISCONNECT THE CHARGER TO A BATTERY

Comfort

Connect

Comfort

Connect

INFO

If the battery clamps are incor-

rectly connected, the reverse

polarity protection will ensure that

the battery and charger are not

damaged.

For batteries mounted inside a

vehicle

1. Connect the red clamp to the bat-

tery's positive pole.

2. Connect the black clamp to the

vehicle chassis remote from the fuel

pipe and the battery.

3. Connect the charger to the wall

socket

4. Disconnect the charger from the wall

socket before disconnecting the battery

5. Disconnect the black clamp before

the red clamp.
Some vehicles may have posi-

tively earthed batteries.

1. Connect the black clamp to the bat-

tery's negative pole.

2. Connect the red clamp to the vehicle

chassis remote from the fuel pipe and

the battery.

3. Connect the charger to the wall

socket

4. Disconnect the charger from the wall

socket before disconnecting the battery

5. Disconnect the red clamp before the

black clamp.

20015075E Manual MXS 5.0, EU. Print file 005.indd 6

2011-10-10 16:49:34

Advertising