Battery types and settings, Charging phases – CTEK MXT 14000 AE User Manual

Page 3

Advertising
background image

EN  •  3

3. Normal charging will be indicated by the following lights: start (1), bulk charging (2), absorption charging (3) or mainte-

nance charging (4). When the maintenance charging lamp illuminates the battery is fully charged. Charging will start 

if the voltage drops. The charger can normally be connected for months. Reconditioning is indicated by the lamp (5) 

illuminating. 

4. If the battery leads have been connected incorrectly, the reverse polarity protection system will ensure that neither the 

charger nor the battery is damaged and is indicated by lamp (0).

5. If nothing happens. If the lamp indicating the setting and the power lamp remain lit but no other lamp illuminates, the 

connection to the battery or chassis may be poor or the battery may be faulty. Another cause may be a lack of voltage in 

the AC Power Supply. Begin by improving the connection between the battery and charger.

6. Charging can be stopped at any time by disconnecting the charger’s AC cord. Always disconnect the AC cord before 

disconnecting the battery leads. When you stop charging a battery installed in a vehicle you should always disconnect 

the battery lead from the chassis before disconnecting the other battery lead.

IMPORTANT INFORMATION

Please note that the battery pack in the 24V system in most cases consists of more than one battery. They are linked up to 

the 24V system, but the individual batteries generally have a lower voltage. Therefore it is important for the charger to be 

connected correctly. 

BATTERY TYPES AND SETTINGS

The charger is programmed according to “PROGRAM DESCRIPTION” with fixed settings and can easily be set for 

different types of batteries or conditions. The following recommendations should, however, only be seen as guidelines. 

Please consult the battery manufacturer for further instructions. 

Settings are made by pressing the “MODE-button “ and stepping forward one press at a time until the required mode is 

reached, the button is then released. After about 2 seconds the charger activates the selected mode. The selected mode 

is saved in a memory in the charger and remains there even if the charger is disconnected from battery and mains.

NORMAL

NORMAL - Normal setting for wet batteries, maintenance free and for most Gel batteries. Some Gel 

batteries prefer a slightly lower charging voltage. Please consult the battery manufacturer when in 

doubt.

SUPPLY

SUPPLY - The charger operates at a constant voltage. This is the maintenance mode for applications 

where maximum capacity from the battery is important, like floor sweepers and golf carts. Note that 

the Spark protection function is suppressed in this mode.

RECOND

RECOND - This mode is used to recover deep discharged flooded batteries where you could expect 

a stratified acid (high acid weight in the bottom, low on top). Check with battery manufacturer when 

in doubt. 

Use this mode with care, because the high voltage will cause some water loss. 32V is normally no 

problem for electronics in 24V system. Consult your supplier when in doubt. Life of light bulbs will be 

reduced at higher voltage. Try to disconnect light from the battery during this phase. Maximum effect 

and minimum risk for electronics is achieved by charging a disconnected battery.

CHARGING PHASES

MXT 14000 AE charges and analyses in eight fully automatic steps.

The battery charger has an 8-step fully automatic charging cycle:

Desulphation

Desulphation with pulses recovers sulphated batteries. Indicates with lamp 1.
Start (Lamp 1)

Start mode for the charging cycle. The start phase continues until the battery’s terminal voltage has risen above the set 

limit, at which point the charger switches to bulk charging. If the terminal voltage has not passed the voltage

limit within 

the time limit, the charger switches to fault mode (lamp 0) and discontinues the charging. If so, the battery is faulty or its 

capacity is too large. 
Bulk (Lamp 2)

Main charge when 80% of charging takes place. The charger delivers maximum current until the terminal voltage has risen 

to the set level. Bulk has a maximum time, at which point the charger automatically switches to Absorption.

Advertising