Program description – CTEK MXT 14000 AE User Manual

Page 6

Advertising
background image

6  •  EN

PROGRAM DESCRIPTION

C

ur

re

nt (

A) V

ol

ta

ge (

V)

Desulphation

Soft Start

Bulk

Absorption

Recovers a 

sulphated battery

Tests the battery

condition

Bulk charge

Peak charge with

minimal fluid loss

MXT 14000 AE PARAMETERS

Mode Desulphation

Soft Start

Bulk

Absorption

PRESET   YES

Max 14A for 4h until the 

voltage reaches 25.2V.

14A for max 20h. 

28.8V for 4h after the 

current dropped to 2.5A, 

max 12h.

Advertising