How to select: voltage check program – CTEK MXS 5.0 CHECK User Manual

Page 2

Advertising
background image

4 • EN

HOW TO USE: VOLTAGE CHECK PROGRAM

WITH SUPPLY PLUG CONNECTED

1. Connect the charger to the battery.
2. Connect the charger to the wall socket. The power lamp will indicate that the mains

cable is connected to the wall socket. The error lamp will indicate if the battery clamps

are incorrectly connected. The reverse polarity protection will ensure that the battery or

charger will not be damaged.

3. Press the MODE-button for about 2 seconds. The three VOLTAGE CHECK result lamps

will flicker, to indicate VOLTAGE CHECK PROGRAM until a selection is chosen. The

lamps in the lower row will indicate the VOLTAGE CHECK PROGRAM selected. To

select another VOLTAGE CHECK PROGRAM, press the MODE-button briefly. The

VOLTAGE CHECK result lamps will flicker again until a result is shown:

REd: Indicates BAD

YELLOW: Indicates FAIR

GREEN: Indicates OK!

4. Exit the VOLTAGE CHECK PROGRAM at any time by pressing the MODE-button for

about 2 seconds.

5. To continue charging, press the MODE-button to select a CHARGING PROGRAM or

OPTION.

HOW TO SELECT: VOLTAGE CHECK PROGRAM

VOLTAGE CHECK PROGRAM: BATTERY

For accurate results, the battery must rest for at least one hour before test.

Select the VOLTAGE CHECK PROGRAM: BATTERY with the MODE-button.

If you get a BAD or

FAIR indication, charge the battery.

Note: When the battery is in very cold conditions (under 5ºC), the battery voltage will

fall, and may be below the level for the green indication, even if it is good. It is always

good for the battery to be fully charged so if you do get a

BAD or FAIR indication,

recharge the battery.

VOLTAGE CHECK PROGRAM: START POWER

This voltage check program checks the battery's performance when cranking.

Select the VOLTAGE CHECK PROGRAM: START POWER with the MODE-button. The

test will start with the OK indication lit. Run the starter motor for a few seconds or until

the engine starts. The VOLTAGE CHECK PROGRAM: START POWER will record the bat-

tery's performance during cranking. A BAD indication shows that the battery is worn out

or discharged. Before replacing the battery try to recharge it.

Note: Even if the check indicates

BAD, the battery may function in the summer but it

will probably fail in the coming winter. To repeat this check, press the MODE-button

repeatedly until VOLTAGE CHECK PROGRAM: START POWER is selected again.

VOLTAGE CHECK PROGRAM: ALTERNATOR
This function will check the alternator or generator performance. At this VOLTAGE

CHECK PROGRAM, it is good to have a second person available to start the car.
1. Select the VOLTAGE CHECK ALTERNATOR with the MODE-button.

2. Start the engine and run it with high idle speed (2000 RPM).
If you get a BAD indication, this means the alternator does not charge the battery

good enough. Contact your service garage immediately. Tip: Charge the battery before

driving.
If the FAIR indication is still lit after running the engine for a minute, the alternator is

working but the voltage level is low. Consult your garage. Charge the battery regularly.

MODE

RECOND

BATTERY START POWER

ALTERNATOR

VOLTAGE CHECK PROGRAM

MXS 5.0

CHECK BY

BATTERY

VOLTAGE CHECK

BAd!

RED

FAIR!

YELLOW

OK!

GREEN

START POWER

VOLTAGE CHECK

ALTERNATOR

VOLTAGE CHECK

Advertising