PROGRAM DESCRIPTION

C

ur

re

nt (

Am

pe

re

s) V

ol

ta

ge (

Vo

lts

)

Desulphation

Soft Start

Bulk

Absorption

Analysis

Recond

Float

Pulse

Recovers a

sulphated battery

Tests the battery

condition

Bulk charge

Peak charge with

minimal fluid loss

Tests whether the

battery retains

the energy

Reconditioning of

a drained battery

Maintenance for

maximum

performance

Maintenance for

maximum

battery life

MULTI XS 15000 PARAMETERS

MODE Desulphation

Soft Start

Bulk

Absorption

Analysis

Recond

Float

Pulse

NORMAL

or

RECOND

YES

Max 15A for 4h until

the voltage reaches

12V.

15A for max 20h.

14.4V until 4h after

the current dropped

to 2.5A, max 12h.

Warning indication

if voltage drops to

12.0V in 3 minutes.

Max 15.8V and 3A

for 4h for deeply

discharged

batteries.Otherwise

for 30 minutes (only

in Recond mode).

13.6V with max 15A

for max 10 days.

Pulse start at 12.9V,

max voltage 14.4V.

SUPPLY

13.6V max 15A.

20

01

07

32

A