Xample, 4 - 24 r, Eceivers with – CTI Products MCN RCD System Planner User Manual

Page 42: Ultiple, Perator, Ositions, Igure, 17 - 24 r, Onsole and, Pc p

Advertising
background image

Appendix C System Examples

Page 38

MCN Comparator Display System Planner

7.4

Example 4 - 24 Receivers with Multiple Operator Positions

The example in Figure 17 shows a much larger system than the previous examples. Three CIB
modules are used to control a total of 24 receivers. The three IIB modules can be used to provide
control of all receivers from the main console. Each PC in the system can control all receivers as well.
The HIB modules provide both local and remote control of all receivers. With the HIB connected
directly to the modem, the comparators can be accessed from anywhere that has a dial-up phone line.

This system assumes the following:

(2) Spectra-TAC Comparator (comparators 1 & 2), 8 receivers each

(1) DIGITAC Comparator (comparator 3), 8 receivers

1000 feet between comparators room and the CEB room

Local PC display in the console electronics room

Dial-up PC for remote monitoring

Console Display using Extended IIBs

All comparators are mounted in the same rack.

The Dial-up HIB and the CIBs for the Spectra-TAC comparators will be rack mounted in same
cabinet as the comparators

CIBs will be connected to Spectra-TAC comparators with blunt-end cables wired directly to the
back of the comparators.

The CIB for the DIGITAC comparator will mount to the rear of the comparator with a Digitac
Bracket and Cabling kit.

IIBs will be rack mounted in the CEB room

The HIB in the CEB room will be mounted under a desk-top using a wall-mount kit.

Punch blocks are used for connection between the IIBs and the consoles CEB (punch blocks are
not shown on the diagram.)

COM 2

COM 1

COM 2

COM 1

CA-80017-100

2

COMPARATORS

HIB

CIB

CIB

CIB

T

MODEM

MODEM

HIB

IIB

IIB

IIB

T

CONSOLE

ELECTRONICS

1

3

P/S

OUT

OUT

OUT

OUT

IN

IN

IN

IN

IN

OUT

IN

IN

IN

OUT

OUT

OUT

P/S

REMOTE PC

LOCAL PC

CONSOLE

Figure 17 - 24 Receivers with Multiple Operator Console and PC Positions

(P/S = Power Supply, T = Network Terminator)

Power is provided to this MCN system from two power supplies. One supply power one HIB module
and all three CIB modules. Another supply power the second HIB module and the three IIB modules.

Advertising