Xample, 6 - m, Ultiple – CTI Products MCN RCD System Planner User Manual

Page 45: Emote, S using, Exb s, Ystem, Xtenders, Igure, 19 m

Advertising
background image

Appendix C System Examples

MCN Comparator Display System Planner

Page 41

7.6

Example 6 - Multiple Remote PCs using EXB System
Extenders

When only one remote PC is needed to monitor remote comparators, a HIB Host Computer Interface
Module and a pair of modems are used. If multiple PCs are required, that method would require
multiple telephone lines, one for each PC.

Figure 19 shows a way to connect multiple PCs to remote comparators using only one phone line.

The

pair of EXB System Extender Modules extend the MCN network at the remote site to the local site.
The remote network of CIB Comparator Interface Modules is essentially re-created at the local site.
Multiple PCs are then connected to the local MCN network through standard HIB Host Computer
Interface Modules. The number of PCs at the local site is limited only by standard MCN system
limitations.

HIB

T

OUT

IN

P/S

EXB

OUT

IN

T

P/S

CIB

CIB

OUT

OUT

IN

IN

OUT

IN

CIB

OUT

IN

T

TO COMPARATORS

LEASED LINE

REMOTE SITE

CA-80185-100

EXB

HIB

T

OUT

IN

COM 2

COM 1

COMPARATOR

DISPLAY

COM 2

COM 1

COMPARATOR

DISPLAY

Figure 19 Multiple Local PC Displays with Remote Comparators using EXB Modules

Systems using EXB System Extender Modules are considered custom designed systems. Please
contact a CTI Products application engineer for help in designing a system.