2.12 Hold Boundary Programming

The entry system hold boundaries establish a set of four-digit entry codes that will latch relay 1 ON,
relay 2 ON, or both relay 1 and relay 2 ON (depending on the divide number programmed and the
hold boundaries that have been programmed) indefinitely. To un-latch the relay(s), an entry code
within the hold boundary is entered on the keypad.

NOTE: Hold boundaries can only be established for the four-digit entry codes. Five-digit entry codes
have no hold boundaries.

1. Press *07 and enter the four-digit master code _ _ _ _ (short beep).

2. Enter a four-digit code for the lower hold boundary _ _ _ _ then press * (short beep).

3. Enter a four-digit code for the upper hold boundary _ _ _ _ then press * (short beep).

4. Press 0# together to end the programming step (long beep).


NOTE: To delete hold boundaries, enter # # # # in steps 2 and 3.

2.13 Time Zone 1 Boundary Programming

Programming the lower and upper boundaries for time zone 1 establishes a set of four-digit entry
codes that will be denied access if the time zone 1 input (terminal 3) is activated. This time zone does
not affect the five-digit entry codes.

1. Press *05 and enter the four-digit master code _ _ _ _ (short beep).

2. Enter a four-digit code for the lower boundary _ _ _ _ then press * (short beep).

3. Enter a four-digit code for the upper boundary _ _ _ _ then press * (short beep).

4. Press 0# together to end the programming step (long beep).


NOTE: To delete time zone 1 boundaries, enter # # # # in steps 2 and 3.

2.14 Time Zone 2 Boundary Programming

Programming the lower and upper boundaries for time zone 2 establishes a set of four-digit entry
codes that will be denied access if the time zone 2 input (terminal 4) is activated. This time zone does
not affect the five-digit entry codes.

1. Press *06 and enter the four-digit master code _ _ _ _ (short beep).

2. Enter a four-digit code for the lower boundary _ _ _ _ then press * (short beep).

3. Enter a four-digit code for the upper boundary _ _ _ _ then press * (short beep).

4. Press 0# together to end the programming step (long beep).