Wiring diagram, Gate 1, Gate 2 – Controlled Products Systems Group LA400-S User Manual

Page 26

Advertising
background image

26

Z22

R91

CLOSE
EDGE

R94

R92

R93

L1

R1

R2

Z1

K5

K2

F3

10A 32V

D1ÿ

OPEN EDGE/

PHOTO

OPEN
PHOTO

CLOSE
PHOTO

J18

R227

R2ÿ 7

Z2ÿ

R223

P1

Z9

Z8

F2

F6

D4

D2

R9

C64

JMPR1

R224

U4

P2

J1

J19

SINGLE

BUTTON

CONTROL

INPUTS

FORCE

BIPART

DELAY

TIMER TO

CLOSE

MIN

MAX

OFF

MAX

OFF

MAX

OPEN

SINGLE BUTTON

RESET

STOP

SHADOW

S1

INTERRUPT

CHGR
OVLD

COM

COM

COM

FUSE
OPEN

LOOP

INPUTS

POWER

BATT 1

BATT 2

F1 20A 32V

R35

D9

Z3

Z4

U3

D1

D27

F5

C11

C13

C12

D15

C2

R4

R1ÿ 1

R1ÿÿ

R9ÿ

Q9

K1

R196

Q22

D8

K3

K4

D21

D22

C4

ACCESSORY

OVLD

D6D6

JMPR2

JMPR2

MOV1

MOV2

DB1

DB1

U2

Z12

24 VAC/

SOLAR

INPUT

GATE 2

MAGLOCK

ALARM

C

C

NC

NO

NO

GRN

WHT

YEL

BLU

RED

BRN

GRN

WHT

YEL

BLU

RED

BRN

F4

10A 32V

F7

24V

24V

COM

OVLD

OVLD

SWITCHED

ACCESSORY

POWER

TIMER

RUNNING

GATE 2

SET

OPEN

LIMIT

SET

CLOSE

LIMIT

LEARN
LIMITS

DIAGNOSTIC

GATE 1

J4

SAVE
MAGLOCK
MODE
EDGE
PHOTO

OFF
OFF

SINGLE

NO
NO

ON
ON
DUAL
NC
NC

LEARN

XMITTER

S8

1 2 3 4 5

O

N

2

1

Flashing Strobe
(optional)

Siren
(optional)

(optional)

Fault Alarm

Solenoid Lock

Maglock

(optional)

ANTENNA

CONNECTION

YELLOW/GREEN

(OR OPTIONAL EARTH GROUND WIRE)

GROUND

G R N

W H T

YE L

B LU

R E D

B R N

GATE 1

G R N

W H T

YE L
B LU

R E D

B R N

K6

EDGE

EDGE

EDGE

OR

OR

EDGE

EDGE

EDGE

OR

OR

PHOTO

PHOTO

OR

OR

OR

OR

PHOTO

PHOTO

OR

PULSING PHOTO

PULSING PHOTO

PULSING PHOTO

24VDC OUTPUT
SWITCHED OFF

IN LOW POWER MODE

OPEN (EXIT LOOP)

SINGLE BUTTON

RESET

STOP

COMMON (+24VDC)
COMMON (+24VDC)

SHADOW LOOP

INTERRUPT LOOP

COMMON (+24VDC)

GATE 2

OR

RED

BLACK

RED

BLACK

BLUE

YELLOW

GATE 1

ACCESSORY

POWER

1. ANTENNA INPUT
2. CLOSE EDGE
3. OPEN EDGE/PHOTO EYE
4. OPEN PHOTO EYE
5. CLOSE PHOTO EYE
6. 24VDC ACCESSORY OUTPUT
7. CONTROL INPUTS/EXIT LOOP
8. LOOP INPUTS, SAFETY/SHADOW
9. TRANSFORMER INPUT/SOLAR INPUT (OPTIONAL)
10. SECOND - OPERATOR ARM CONNECTION
11. 24VDC ACCESSORY OUTPUT
12. MASTER OPERATOR ARM CONNECTION

13. MAGLOCK/SOLENOID OUTPUT
14. FAULT ALARM OUTPUT
15. BATTERY INPUT #1
16. BATTERY INPUT #2
17. DIP SWITCH, S1
18. LEARN XMITTER
19. MASTER GATE JOG
20. LIMIT SET
21. SECOND GATE JOG
22. SBC (SINGLE BUTTON CONTROL)
23. FORCE SET
24. BIPART DELAY SET
25. TIMER TO CLOSE SET

7

8

15

2

3

4

5

6

1

16

23

24

25

9

21

20

19

10

11

12

18

14

22

13

17

NOTE: Batteries must be connected
to operate.

NOTE: Yellow/green wire must
be disconnected when earth
ground rod is installed.

To protect against fire and electrocution:

• DISCONNECT power and battery BEFORE
installing or servicing operator.

• Replace ONLY with fuse of same type and rating.

W I R I N G D I A G R A M