Opening
Pressing this button will cause the gate to open.

Stop
Pressing this button will cause the gate to
stop moving.

Closing
Pressing this button will cause the gate to close.

Reset E.R.D. Board
Push all three pushbuttons for approximately
5 seconds. All three L.E.D.’s should blink.

"Intelligate" Control Board

Three pushbuttons are located under the dip switches for operation of the gate (see Figure 11). The opening,
stop and closing buttons can be utilized to set limit switches and verify proper system operation when
installing or servicing an operator.

PUSHBUTTON CONTROLS

MASTER / SLAVE INSTALLATION

L.E.D.’s light up when Opening,

Closing or Stopped

Figure 11

Figure 10

Set Dip Switch (C8) "Slave Mode" to ON for
slave operator.
(RH) Right Hand operation requires Dip Switch
(C7) "Left/Right" to be ON.

Route low-voltage wires for

Master/Slave in a conduit

separate from power.

Use 3-stranded, shielded wires

(not supplied) from Master to Slave.

Use jumper

JP7 to JP7

Conduit for Power