TERMINAL STRIP CONNECTIONS

Terminal # 1 - COMMON:

Low voltage common.

Terminal # 2 - REV LOOP:

Stops the gate from closing. If the gate is open,

it holds the gate open. If the gate is closing, it

stops and reopens the gate. If the gate is closed,

the gate will remain closed. The function can be

altered with Dip Switch "C" 4 (see “Dip Switch

Configuration”). Used with loop detectors, photo

eyes, safety edges on front side of gate etc.

Becomes active with a closed contact to com-

mon.

Terminal # 3 - CLOSE:

Closes the gate. Used with three button stations

or pushbuttons. Becomes active with a closed

contact to common.

Terminal # 4 - FIREBOX:

Opens the gate. Used with fire department key

switches & controls. Opens with closed contact

to common. Closes immediately when closed

contact on common is removed.

Terminal # 5 - EXIT:

Opens the gate. Used with loop detectors, photo

eyes, keypads, phone entry systems, three-but-

ton stations…etc. Becomes active with a closed

contact to common.

Terminal # 6 - PHANTOM:

Keeps the gate open when the open limit switch

is activated. Used with loop detectors. Becomes

active with a closed contact to common.

Terminal # 7 - RADIO:

Operation depends on dip switch "C" 3 (See “Dip

Switch Configuration”). Used with an RF receiver

or pushbutton. Becomes active with a closed

contact to common.

Terminal # 8 - EDGE:

When triggered the gate will stop. The gate

will remain stopped until the detector is cleared.

Once the detector is cleared, the operator will

resume normal operation. If triggered twice

before reaching a limit switch, the alarm will

sound for 6 minutes and the control board will not

accept any commands. After the 6 minutes the

24 VDC is removed from the alarm connection

and the board resets to normal operation.
Used with safety edge mounted on post or back

of gate.

Terminal # 9 and 10 - LIMIT 1 & LIMIT 2:

Direction depends on Dip Switch "C" 7 (See “Dip

Switch Configuration”). Stops the motor from

moving in one direction. These wires are preset

in factory and should not be moved. Becomes

active with a closed contact to common.

Terminal # 11 and 12 - COMMON:

Low voltage common.

Terminal # 13 - +24 VAC:

Provides 24 VAC for peripheral accessories.

Terminal # 14 and 15 - MAG (-) & MAG (+):

Supplies 24 VDC to a Magnetic Lock when the

gate is closing or closed. If gate is opening or

opened, then no power is supplied. Leave open

if not used.

Terminal # 16 - M BRAKE:

Used ONLY on the Ram 50 Operator. If while the

gate is closed someone or something tries to

manually open the gate without a proper signal

(keypad, exit loop, radio signal…), the motor will

lock up for 6 minutes. After the 6 minutes, the

operator will then secure close the gate.

Terminal # 17 and 18 - MOTOR 1 & MOTOR 2:

Supplies power to the motor. Direction depends

on Dip Switch "C" 7 (see “Dip Switch Configura-

tion”). These wires are preset and connected in

the factory and should not be moved.

Terminal # 19 and 20 - AC HOT & NEUTRAL:

110 VAC or 220 VAC to power the operator.

Voltage is predetermined at factory and cannot

be changed by the installer or technician.