DIP SWITCH "B"

DIP SWITCH CONFIGURATION

DIP SWITCH "A"

Dip Switch "A" 1, 2 & 3; AUTOMATIC TIMER TO CLOSE GATE

‘0’ is “OFF” ‘1’ is “ON”

Switch

1

2

3

Gate Open Duration:

1

1

1

60 seconds

1

1

0

45 seconds

1

0

1

30 seconds

1

0

0

15 seconds

0

1

1

10 seconds

0

1

0

05 seconds

0

0

1

00 seconds

0

0

0

Disabled - command required to close

Dip Switch "A" 4; 1/2 HP E.R.D.

Sw. Function:

OFF Most sensitive or when using 3/4 hp motor.

ON

Stronger (Less sensitive) E.R.D. for 1/2 hp motors.

Dip Switch "B" 1; Not in use at this time.

Leave in the ‘Off’ position.

Dip Switch "B" 2; “PREWARN”

Sw.

Pre Warning Relay:

OFF Normal

Operation

ON

Adds a 3-second delay before the gate moves in

any direction. During This 3 second delay the

PREWARN Relay maintains a closed contact.

Dip Switch "B" 3; “CONSTANT WARN”

(Constant warning when gate is in motion).

Sw. Function:

OFF No

effect.

ON

Triggers the prewarn relay to maintain a closed
contact while gate is in motion.

Dip Switch "B" 6; Not in use at this time.

Leave in the ‘Off’ position.

Dip Switch "B" 7; Not in use at this time.

Leave in the ‘Off’ position.

Dip Switch "B" 8; 3/4 HP E.R.D.

Sw. Function:

OFF Most sensitive or when using a 1/2 hp motors.

ON

Stronger (Less sensitive) E.R.D. for 3/4 hp motors.

Dip Switch Up for "ON"

Dip Switch Down for "OFF"

Figure 12

Dip Switch "B" 4 & 5; “ADDRESS 1 & ADDRESS 0”

Up to four separate entrance addresses are available for
installations with multiple entrance or exit locations.
Master and slave gates that work together should be set to
the same address. (Side gates use the address setup)

Sw. 4 5 Function:

0 0 Default - Entrance 1

0 1 Entrance 2

1 0 Entrance 3

1 1 Entrance 4