Advanced controller programming (cont.), Reset cycle count, Maintenance alert trigger – Controlled Products Systems Group SWG-111 User Manual

Page 18: Mid-travel stop position, Anti-tailgate enable, Radio enable, Antenna installation

Advertising
background image

SWG Swing Gate Operator Installation Guide

- 16 -

P1227 Revision X5 2-13-2013

Advanced Controller Programming (Cont.)

Reset Cycle Count

The Controller counts of the number of times the operator has been
cycled full open and close. The cycle count can be displayed. The display
will scroll the cycle count number, fl ashing two digits at a time from left
to right.

To reset the Cycle Count, press and hold the ENTER button for 2 seconds
while the Cycle Count is displayed.

If the Maintenance Alert has been triggered, resetting the Cycle Count
will also reset the Maintenance Alert indicator.

Maintenance Alert Trigger

The Controller has a MAINT ALERT indicator that can be programmed
to light when the number of activations exceeds a set number of cycles.

The factory default sets the Maintenance Alert Trigger to 10,000 cycles.
The Maintenance Alert Trigger can be programmed for 5, 10, 15, or 25
thousand cycles.

The Maintenance Cycle Count can be reset independently from the
operator’s absolute Cycle Count.

Mid-travel Stop Position

The Controller can be programmed so the gate will stop at a mid-travel
point instead of fully opening. This can be useful in installations where a
large gate, that takes a long time to open and close fully, only needs to
be opened partway to allow traffi c to pass.

The factory default sets the Controller for full open operation. Alternately,
the Controller can be programmed to open for 1 to 99 seconds then stop,
before reaching the open limit.

When a Mid-travel Stop Position time has been programmed, the gate
will still fully open if the Fire Department input is triggered, if the OPEN
button is held down beyond the Mid-travel Stop Position, or a close
obstruction or reverse loop input is triggered.

NOTE: The Mid-travel Stop feature is disabled when dual gate

operation is enabled for paired units.

Anti-tailgate Enable

The factory default sets the Anti-tailgate Enable to OFF. With this setting,
during a gate cycle, after the shadow loop has been triggered by the
vehicle and then has cleared after the vehicle passes, the Auto Close
Timer or a CLOSE command is required to begin closing the gate.

If the Anti-tailgate Enable is set to ON, the gate will close immediately
as soon as the shadow loop has cleared. Any subsequent shadow loop
triggers while the gate is closing will stop the gate. When the shadow loop
clears, the gate will continue closing.

Radio Enable

The Controller contains a built-in MegaCode

®

radio receiver to allow

activation from up to 40 access control transmitters and two Model MGT
(gate edge) transmitters. The factory default enables the internal radio
receiver. Alternately, the internal receiver can be disabled.

Antenna Installation

The Controller is supplied with a local whip antenna installed. If using a
remote antenna, remove the whip antenna and connect coax cable from
the antenna to the ANTENNA connector.

FUNCTION

SETS THIS MAINTENANCE ALERT TRIGGER
FOR 5, 10, 15, OR 25 THOUSAND CYCLES

DISABLES THE MAINTENANCE ALERT
FUNCTION

RESETS THE MAINTENANCE ALERT
INDICATOR AND SETS THE MAINTENANCE
ALERT COUNT TO ZERO

OPTIONS

PRESS UP OR

DOWN TO CYCLE

THROUGH OPTIONS

PRESS ENTER TO

SELECT AN OPTION

MAINTENANCE

ALERT TRIGGER

"MA"

FUNCTION

PRESS ENTER TO START THE CYCLE COUNT DISPLAY

1ST DISPLAY

NOTE: PRESS ENTER FOR 2 SECONDS
WHILE THE "CT" FUNCTION IS DISPLAYED
TO RESET THE CYCLE COUNT TO ZERO

RESET CYCLE

COUNT

"CT"

2ND DISPLAY

3RD DISPLAY

4TH DISPLAY

EXAMPLE ABOVE SHOWS 10,420 CYCLES

DECIMAL POINT LIT
ON 4TH DISPLAY

FUNCTION

SET LENGTH OF OPENING TIME
FROM 1 TO 99 SECONDS

MID-TRAVEL STOP DISABLED
(GATE RUNS FULL TRAVEL)

OPTIONS

PRESS UP OR

DOWN TO CYCLE

THROUGH OPTIONS

PRESS ENTER TO

SELECT AN OPTION

MID-TRAVEL

STOP POSITION

"MT"

FUNCTION

ANTI-TAILGATE ENABLE OFF
GATE REQUIRES AUTO OR MANUAL CLOSE

OPTIONS

PRESS UP OR

DOWN TO CYCLE

THROUGH OPTIONS

PRESS ENTER TO

SELECT AN OPTION

ANTI-TAILGATE

ENABLE

"AT"

ANTI-TAILGATE ENABLE ON
GATE CLOSES WHEN SHADOW LOOP CLEARS

FUNCTION

INTERNAL RADIO RECEIVER DISABLED

OPTIONS

PRESS UP OR

DOWN TO CYCLE

THROUGH OPTIONS

PRESS ENTER TO

SELECT AN OPTION

RADIO

ENABLE

"RA"

INTERNAL RADIO RECEIVER ENABLED

Advertising
This manual is related to the following products: