Advanced Controller Programming (Cont.)

Radio Transmitter Learn

The Controller’s built-in MegaCode

®

radio receiver can store the IDs of up to

40 transmitters. Refer to the fi gure for the steps required to learn transmitters.

NOTE: This function will NOT be displayed if the transmitter memory

is full, or if the radio receiver is disabled.

Radio Transmitter Delete

Transmitters can be deleted from the Controller’s memory either
individually, or all at the same time. Refer to the fi gure for the steps
required to delete transmitters.

NOTE: This function will NOT be displayed if no transmitters are

stored in memory, or if the radio receiver is disabled.

MGT Obstacle Transmitter Learn

The Controller supports one or two Model MGT Obstacle Transmitters.
The transmitters can be programmed to function as Open Obstruction,
Close Obstruction, Reverse, or Stop. Refer to the fi gure for the steps
required to learn MGT transmitters.

NOTE: This function will NOT be displayed if two MGT transmitters

are already stored in memory, or if the radio receiver is disabled.

MGT Obstacle Transmitter Delete

MGT transmitters can be deleted from the Controller’s memory either
individually, or all at the same time. Refer to the fi gure for the steps
required to delete MGT transmitters.

NOTE: This function will NOT be displayed if no MGT transmitters are

stored in memory, or if the radio receiver is disabled.

Motor Type Selection

The factory sets the default for the Controller to match the type of motor in
the operator. If required, change the motor selection option to a different
type of motor used in the operator. The options available are:

• AC Motor Only
• DC Motor Only with Mechanical Braking
• DC Motor with Electronic Soft Start/Stop
• 3 Phase AC Motor
• AC Motor with DC Motor Backup with Mechanical Braking
• AC Motor with DC Motor Backup with Electronic Soft Start/Stop

Reset Controller to Factory Defaults

The Controller can be reset with this function. ALL PROGRAMMED
DATA WILL BE LOST
, and the factory defaults will be loaded. This
function will not erase radio transmitters, current sense values, or motor
type. Transmitters must be deleted with the two functions above.

FUNCTION

TO DELETE ALL MGT TRANSMITTERS, PRESS ENTER FOR
2 SECONDS, (TO EXIT WITHOUT DELETING ANY, QUICKLY
PRESS ENTER)

ERASE MGT

TRANSMITTERS

"MD" WILL BLINK FOR 30 SECONDS WHILE THE CONTROLLER
IS READY TO DELETE ALL MGT TRANSMITTERS

"MD"

ENTER

PRESS ENTER

ENTER

THE DISPLAY WILL SHOW "DELETE ALL" AND THE
CONTROLLER RETURNS TO PROGRAMMING MODE

FUNCTION

TO DELETE ALL TRANSMITTERS, PRESS ENTER FOR
2 SECONDS, OR TO PICK TRANSMITTERS GO TO NEXT STEP

DELETE

TRANSMITTERS

"TD" WILL BLINK FOR 30 SECONDS WHILE THE CONTROLLER
IS READY TO DELETE ONE OR MORE TRANSMITTERS,
(TO EXIT WITHOUT DELETING ANY, PRESS ENTER)

"TD"

ENTER

PRESS ENTER

ENTER

OR

UP

DOWN

ENTER

PRESS UP OR DOWN TO SCROLL THROUGH THE LIST
OF TRANSMITTER ID NUMBERS

THE TRANSMITTER ID NUMBER IS DISPLAYED
(TO EXIT WITHOUT DELETING, PRESS ENTER)
(TO PICK A DIFFERENT TRANSMITTER ID, PRESS UP OR DOWN)

PRESS ENTER FOR 2 SECONDS TO DELETE THE
TRANSMITTER DISPLAYED

FUNCTION

ACTIVATE THE MGT TRANSMITTER, THE DISPLAY WILL
FLASH "rE" - IF THE TRANSMITTER IS ALREADY ENTERED,
"DU" WILL BE DISPLAYED, IF DECODE IS BAD "ERROR" WILL
BE DISPLAYED

LEARN MGT

TRANSMITTERS

PRESS ENTER, "ML" WILL BLINK FOR 30 SECONDS WHILE
THE CONTROLLER IS READY TO LEARN AN MGT
TRANSMITTER

"ML"

ENTER

OR

UP

DOWN

ENTER

DISPLAY WILL SHOW "--" FOR 5 SECONDS, THEN SHOW THE
TRANSMITTER'S ID NUMBER - REPEAT STEPS FOR
SECOND MGT TRANSMITTER IF USED

PRESS ENTER TO ACCEPT THE SELECTION

PRESS UP OR DOWN TO SELECT THE MGT FUNCTION:
"rE" = REVERSE "St" = STOP
"OP" = OPEN OBSTRUCTION "CL" = CLOSE OBSTRUCTION

FUNCTION

ACTIVATE THE TRANSMITTER

DISPLAY WILL SHOW "- -" THEN THE
TRANSMITTER ID NUMBER - IF TRANSMITTER
IS ALREADY ENTERED, "dU" WILL BE DISPLAYED,
IF DECODE IS BAD "ERROR" WILL BE DISPLAYED

LEARN

TRANSMITTERS

"TL" WILL BLINK FOR 30 SECONDS WHILE
THE CONTROLLER IS READY TO
LEARN A TRANSMITTER

"TL"

ENTER

PRESS ENTER (ONCE FOR EACH TRANSMITTER,
UP TO 40 TRANSMITTERS TOTAL)

FUNCTION

RESET TO

FACTORY DEFAULTS

"CL"

ENTER

WHILE "CL" IS DISPLAYED, PRESS ENTER

ALL PROGRAMMED DATA WILL BE CLEARED
AND THE FACTORY DEFAULTS WILL BE
STORED IN MEMORY.

NOTE: THIS FUNCTION WILL NOT ERASE
TRANSMITTERS, CURRENT SENSE VALUES,
OR MOTOR TYPE.

FUNCTION

DC MOTOR ONLY WITH BRAKING

AC MOTOR ONLY

DC MOTOR WITH SOFT START/STOP

AC MOTOR PRIMARY WITH
DC MOTOR BACKUP WITH BRAKING

OPTIONS

PRESS UP OR

DOWN TO CYCLE

THROUGH OPTIONS

PRESS ENTER TO

SELECT AN OPTION

MOTOR TYPE

SELECTION

NOTE: SELECTION

MUST MATCH

MOTOR BOARD!

"MO"

3 PHASE AC MOTOR

AC MOTOR PRIMARY WITH
DC MOTOR BACKUP WITH SOFT START/STOP