Introduction

The American Access Systems (AAS) PhoneLink unit is a well-built, reliable telephone entry system. The heavy gauge,
powder-coated enclosure with stainless steel faceplate, mounts directly to a pedestal or can be surface mounted.

Before Installation

To take full advantage of the 24-month limited warranty, you must register with American Access Systems, Inc. Please
read and review the Warranty (page 3), complete the enclosed Warranty Registration card and send it to:

Security Brands, Inc.

Warranty Registration

1675 West Yale Ave.

Englewood, CO 80110

Important Tips

1. The PhoneLink unit contains static sensitive components. Use proper grounding techniques during installation to
prevent damage to circuit board. 2. 3. Additional surge protection is highly recommended to provide extra lightning
protection. Electrical Safety Advisory Notice: American Access Systems, Inc. recommends the installation of an AC
surge arrestor in the AC outlet from which the equipment is powered. 4. 5. Please follow the instructions in this manual
carefully to prevent problems during installation and programming.6. 7. American Access Systems cannot guarantee
compatibly with all telephones and accessories (answering machines, caller ID, etc.)

Installation

Proper wire size is necessary for a good and trouble-free installation. Follow the tables below for your installation.

DC Power Wire Size

Distance (in feet)

AC Power Wire Size

18 AWG

30’ or less

18 AWG

18 AWG

30’ to 75’

16 AWG

18 AWG

75’ to 150’

12 AWG

16 AWG

150’ to 250’

10 AWG

12 AWG

250’ to 500”

N/A

Wiring from Bypass Board

Type of Wire

Recommended

To Telco Box

18 to 24 Gauge twisted pair
shielded

Belden #9502 or equivalent

To PhoneLink Controller

18 to 24 Gauge twisted pair
shielded

Belden #9502 or equivalent

Wiring from PhoneLink

Type of Wire

Recommended

To the 12V AC/DC power source

2 conductor cable

18 gauge stranded

To gate operator, door strike, or
magnetic strike

2 conductor cable

Device manufacturer specs

To door strike power supply(if used)

2 conductor cable

Device manufacturer specs

To earth ground

12 AWG copper wire

Belden #9912 or equivalent