Good tones and error tones, Resetting the unit, Master reset – American Access Systems PhoneAire - 16-1050 User Manual

Page 14: Unit reset, Idle mode

Advertising
background image

Page 14 American Access Systems / Security Brands, Inc.

good Tones and error Tones

The PhoneAire unit will sound a tone each time a key is pressed. The “ * “ key serves as the clear key and a double
tone will be heard any time the “ * “ key is pressed.

A “GOOD TONE” is represented by an oscillating high tone. An “ERROR TONE” is represented by a single low tone.

The Red and Yellow LED’S

• Two colored LED’s are in the face of the unit. The red LED illuminates during the duration of the relay(s)

activation period. The yellow LED illuminates while the unit is in the program mode.

• During memory erasure or setup the LED’s will flash.

resetting the unit

Your unit provides two very distinct types of resets, a Master Reset, and a Unit Reset. It is important to understand
when to use each.

• A MASTER Reset should be done in the event that you lose or forget your MASTER code or, if the unit

is in the Latch or Sleep mode and the Latch or Sleep code is lost or forgotten. When a Unit Reset is
performed, the MASTER code is reset to the factory default -- 1 2 5 1. This reset will not affect codes and
other unit programming. It simply resets the MASTER code to 1 2 5 1.

• A Unit Reset is provided should it ever become necessary to completely reset the PhoneAire back to

the initial factory defaults. Be careful … Unit RESET will DELETE ALL ACCESS & FUNCTION CODES and the
MASTER code will be set back to 1 2 5 1. All coding and programming is also lost when a Unit Reset is
completed.

Master reset

(refer to the 30-028 circuit Board Transmitter schematic)

Follow these steps precisely. If you make an error, the unit will ERROR and you will have to

start over. Open the face plate of the unit to access the circuit board.

• Press and hold down SW RESET button on the circuit board.

• Press and release HW RESET button. Unit will beep continually.

• Release SW Reset button.

• Unit will issue one tone.

• Press *** on keypad.

• Unit will beep continually.

• Press and release HW RESET button.

• The unit will issue three GOOD TONE’s and the MASTER code will be reset to 1 2 5 1.

• If you previously were in the sleep or latch mode, the unit will return to the idle state.

unit reset

(!!!!! WArning: All codes Will Be deleTed FroM MeMory !!!!!)

(refer to the 30-028 circuit Board Transmitter schematic)
Follow these steps precisely. If you make an error, the unit will ERROR and you must start over.

• Press and hold down the SW RESET button on the circuit board. At the same time, press and then release

the HW RESET button. Unit will begin to beep repeatedly.

• Release SW RESET button and enter “# * #”. The unit will sound a GOOD TONE.
• Enter 1 2 5 1 on the keypad. The unit will flash the LED’s several times and then again will begin to beep

repeatedly.

• Press and release HW RESET button.
• The unit will issue three GOOD TONE’s and the MASTER code will be reset to 1 2 5 1.
• The PhoneAire is now completely reset to factory defaults.

idle Mode

The Idle mode is the normal operating mode. When in the Idle mode the unit is ready to accept data from the