The Program Mode

The Program Mode is the mode of operation you use to enter, delete, or change access codes or set specific features
of the unit.

The Program Mode is accessed by entering the “MASTER CODE” from the keypad. You will receive a GOOD TONE
and the yellow LED will light, indicating that you are in the Program Mode. You then will have approximately 30
seconds between key presses. If this time is exceeded, you will receive an ERROR and be exited from the program
mode. The * and # keys
The * and # keys serve specific functions while in the Idle or Program mode. The * key is always the clear key and a
double beep will be heard any time the * is pressed. You should use this key if you make an entry error. The # key also
serves as the clear key in the idle mode. In the program mode however, it serves as the exit key and will at any time
when depressed, exit you from the program mode.

Programming the gate

To access the program mode, enter the MASTER CODE. If the MASTER code is valid the yellow LED will come on and
the individual will be prompted with a GOOD TONE to enter a number corresponding to a SUB-MODE. Remember:
MASTER Code will not activate control relay. (MASTER CODE) + (Number corresponding to Sub-Mode). Once in the
program mode, the individual will have 30 seconds between key presses or the unit will ERROR and exit the program
mode. A person desiring to exit the program mode may do so by simply pressing the # key at any time. There are 10
different SUB-MODES to choose from. They are as follows:

suB-Mode description

1

Program Access Codes (Relay A)

2

Delete Codes

3

Change MASTER Code

4

Set Sleep Code Latch Code and/or Call Forwarding

5

Set One Shot Code

6

Set Relay Output Time

7

Program Access Codes (Relay B)

8

Enable / Disable “3 Strikes-You’re Out”

9

Program Event Input

0

Erase Memory

sub-Mode 1 (Program relay A Access codes)

To program new relay A access codes enter the following:

(MAsTer code) + 1 + (neW code) + (neXT neW code) etc, then ( # ) to exit program mode
Select any 4-digit code you wish. If you receive an ERROR TONE after entry, the new code is already being used.
Select another 4-digit code. The unit will respond with a GOOD TONE with the acceptance of each new Relay
A code. You may continue entering Relay A codes until you finish (Press #), or the memory becomes full. You will
automatically be exited from the program mode if the memory reaches capacity. When memory is full you will not
be able to enter this Sub-Mode and will receive an ERROR if entry is attempted.

sub-Mode 2 (delete codes)

To delete codes enter the following;

(MAsTer code) + 2 + (code To Be deleTed)
You can delete any Access or Function code that you wish with the exception of the MASTER CODE. If the code you
wish to delete is not found in memory, the unit will respond with an ERROR and wait for another code to be entered.
A GOOD TONE will be sounded once the code has been found and deleted. You may continue deleting codes until
you finish (Press #).

sub-Mode 3 (change MAsTer code)

To change your MAsTer code, enter the following;

(current MAsTer code) + 3 + (new MAsTer code)
Select any 4 digit MASTER code you wish. If you receive an ERROR TONE it means the code you have entered
is already in use; select another code. The unit will respond with a GOOD TONE when the new MASTER Code is
accepted, and you will be exited from the program mode. MAKE SURE TO WRITE THE NEW MASTER CODE DOWN.