Controlled Products Systems Group 26SASM User Manual

Page 13

Advertising
background image

To deactivate the Timed Antipassback feature, place the “0” card on the
TOUCH CARD

®

reader plate and remove it. Then place the “*” card on

the TOUCH CARD

®

reader place and remove it. Then place the “SET

TIMER” card on the TOUCH CARD

®

reader plate and remove it.

0 +

*

+ SET TIMER

ANTIPASSBACK WAITING TIME. The antipassback waiting time may be
set to any number of minutes from 1 to 99. However, the actual waiting
time will fl uctuate between the time set and twice the time set.
Thus,
if the antipassback time is set to 5 minutes, users will have to wait a
minimum of 5 minutes and a maximum of 10 minutes before reentry will
be allowed. Setting the antipassback waiting time to 0 will disable
the Antipassback feature and reentry will be allowed immediately.
See above to re-activate the Antipassback feature.

To set the antipassback waiting time, place on the TOUCH CARD

®

reader plate the sequence of cards representing the number of minutes
of the minimum waiting period (1 to 99), then place the “*” card on
the TOUCH CARD

®

reader place and remove it, then place the “SET

TIMER” card on the TOUCH CARD

®

reader plate and remove it.


Example: Set antipassback waiting time to 3 minutes.

Place the “3” card on the TOUCH CARD

®

reader plate, remove it,

and place the “*” on the TOUCH CARD

®

reader plate, remove it, and

place the “SET TIMER” card on the TOUCH CARD

®

reader plate,

and remove it.

3 +

*

+ SET TIMER

Secura Key • 9