FLUSH MOUNT WITH 5S BOX (See Figure 9)
1. Use the wall cutout template provided. Locate template on
the wall. Transfer appropriate cutout corner locations to the
wall with a pointed instrument.
2. Draw lines from point to point, outlining cutout.
3. Cut out opening, being careful not to make opening larger
than indicated on the template.
4. Place mounting plate against wall in its proper location.
Using it as a template, mark four holes in corners. Remove
faceplate, and using appropriate drill, drill four holes for
appropriate fasteners (8-32 fasteners are recommended).
5. Fasten mounting plate to 5S box using the four 8-32 flat head
screws provided. (When running wires to the 5S box, don’t use
the center top hole as it will interfere with the housing lock.)
6. Secure mounting plate and 5S box to wall. Screws must be
flat head countersunk #6 or #8. Make sure any cables have
been pulled into the box prior to securing assembly to wall.
For an outdoor installation, silicone sealant is recommended
between the mounting plate and the wall.
7. Be sure all appropriate wiring has been connected to the
terminal board and then plug the terminal board cable into
the socket on the circuit board (see wiring instructions).