Appendix a - troubleshooting, Appendix b - how to get assistance – Impulse 2108 User Manual

Page 9

Advertising
background image

© Sealevel Systems, Inc.

- 7 -

SeaLINK+232.PC User Manual

Appendix A - Troubleshooting

Sealevel Software is supplied with the Sealevel Systems adapter and may be used in
the troubleshooting procedures. Using this software and following these simple steps
can eliminate most common problems without the need to call Technical Support.

1. If your adapter isn’t working, first check to make sure that USB support is

enabled in the System BIOS and it is functioning properly in the operating
system. This can be done by using either the Windows 98/ME or Windows 2000
Device Manager.

2. Ensure that the Sealevel Systems software has been installed on the machine so

that the necessary files are in place to complete the installation.

3. When the SeaLINK+232.PC is configured properly, Sealevel’s WinSSD utility

and the supplied loopback plug can be used to check communications. The
supplied loopback plug connects TD to RD. If you decide to test the Modem
Control Signals, a full pin loopback plug will be required. Details on loopback
plugs are included within WinSSD. Contact Sealevel Systems if you need further
assistance.

4. When testing the SeaLINK+232.PC in loopback mode, you should see both the

TD and RD echoed as data on the screen. The loopback test first transmits a HEX
pattern, 55AA, and then an ASCII string of data. If this test passes, then the
SeaLINK+232.PC is ready for use in your application.

5. Always use the Sealevel Systems diagnostic software when troubleshooting a

problem. This will eliminate any software issues from the equation.

If these steps do not solve your problem, please call Sealevel Systems’ Technical
Support, (864) 843-4343. Our technical support is free and available from 8:00AM-
5PM Eastern Time Monday through Friday. For email support contact

mailto:[email protected]

.