Hardware configuration, Rs-232/422/485, Ulti – Impulse 2113 User Manual

Page 9: Nterface, Roducts

Advertising
background image

Hardware Configuration

RS-232/422/485 Multi-Interface Products


Items# 2109, 2113, 2209, 2213

Dip switches on SeaLINK USB multi-interface serial adapters provide the ability to
communicate with RS-232, RS-422 or RS-485 devices. These switches are also used
to set RS-485 enable modes and termination options. Single port models have a
single eight-position dip switch. Two port models have a pair of eight-position dip
switches allowing each port to be individually configured. All configuration changes
can be made without opening the enclosure.

Dip Switches

Switch ON

OFF

8

2 Wire –

4 Wire –

7

2 Wire +

4 Wire +

6 RD

1K

PU

5 RD

1K

PD

4 120Ω Termination

3

Echo Off

Echo On

2 RS-485

RS-422

1 RS-422/485

RS-232

Switch Function

8

RS-485 Option, OFF for RS-232, RS-422
ON: Connects TX– and RX– for two-wire operation
OFF: Separates TX– and RX– for four-wire operation

7

RS-485 Option, OFF for RS-232, RS-422
ON: Connects TX+ and RX+ for two-wire operation
OFF: Separates TX+ and RX+ for four-wire operation

6

RS-485 Option, OFF for RS-232, RS-422
ON: Adds a 1K Ω pull-up resistor to RX+
OFF: Leaves RX+ floating

5

RS-485 Option, OFF for RS-232, RS-422
ON: Adds a 1K Ω pull-down resistor to RX–
OFF: Leaves RX– floating

4

RS-422, RS-485 Option, OFF for RS-232
ON: Adds a 120Ω termination resistor between RX+ and RX–
OFF: No line termination

3

Two-Wire RS-485 Option, OFF for RS-232, RS-422, Four-Wire RS-485
ON: ECHO Off. The receiver is disabled when the transmitter is enabled.
In a two-wire setup the receiver will not echo back transmitted data
OFF: ECHO On. The receiver is always enabled. In a two-wire setup the
receiver will echo back all transmitted data

2 Mode

Selection

ON: RS-485 mode. The transmitter lines TX+ and TX– are switched to
high impedance when the device is not actively transmitting data
OFF: RS-422 mode. The transmitter lines TX+ and TX– are always driven

1 Mode

Selection

ON: RS-422, RS-485 mode
OFF: RS-232 mode

© Sealevel Systems, Inc.

- 7 -

SeaLINK DIN Rail USB Serial Manual

Advertising
This manual is related to the following products: