Click on the Communication tab to view the communication parameters that you used to
establish default communications with your transmitter. You can reselect Baud Rate, Device
Address
, Serial Protocol, Full/Half Duplex, even though you may have selected different
values to establish initial communications with your PC. You can also define a Custom
Recognition Character
in lieu of the default *.

Ignore Output Items, Output Filter, Output Rate, CR (LF), RTS Type, Include Alarm Data,
Include LF, and Transmission Chars. These items only apply to data transmission by a
counter, not to operation as a remote display.

The Remote Display “C” data entry fields will appear if you have selected Rmt Disply C
under the Input+Display tab to allow data extraction from a longer data string. You can
specify:

Start Char = the decimal ASCII character designating the beginning of a string.

Stop Char = the decimal ASCII character designating the end of the string.

Skip No. = the decimal number of characters following the Start Char to be ignored.

Show No. = the decimal number of characters immediately following the ignored

characters to be displayed.

Example: *ABCD-123.45EFG#HIJK* etc.

Start = *, Skip = 4, Show = 7, Stop = #, data displayed = -123.45

For the list of 127 possible ASCII start and stop characters and the corresponding decimal
values to be entered, click on ASCII Char Table.