Laurel Electronics LAUREATE SERIES 2 COUNTER-TIMER-SERIAL INPUT METER User Manual

Page 65

Advertising
background image

65

Press Menu
Key

Press Digit Select
Key

Press Value Select
Key

_00000U

Half or full duplex

0

Full duplex

1

Half duplex

_00000U

Recognition characters,
start & stop characters.

Special characters have to
be download via Instrument
Setup software.

0

* (asterisk) is recognition character.

No start & stop characters.

1

Custom recognition character.

No start & stop characters.

2

* (asterisk) is recognition character.

Special start & stop characters.

3

Custom recognition characters.

Special start & stop characters.

_00000U

RTS mode

0

Normal RTS

1

Single transmission

_00000U

CR (LF) termination cha-
racters.

0

Only at end of all items

1

At end of each item

.

Ser 3

.

Serial Setup 3

_00000U

Data sent in continuous
mode

0

All Active Items

1

Item #1 only

2

Item #2 only (if active)

3

Item #3 only (if active)

4

Peak only

5

Displayed Item

6

Valley only

7

All Active Items + Peak + Valley

___000U

Modbus* ASCII gap timeout

0

1 sec

1

3 sec

2

5 sec

3

10 sec

___000U

Serial protocol

0

Custom ASCII*

1

Modbus* RTU

2

Modbus* ASCII

Ser 4

.

Serial Setup 4

___000U

Parity

0

None

1

Odd

2

Even

_

Addr

Modbus Address

___000 ___000 ___000

Select digit to flash.

__158

Select

0

thru

9

for flashing digit.

Address range is 1 to 247.

* See Glossary for explanation of item.