Press Menu
Key
Press Digit Select
Key
Press Value Select
Key
_00000U
Half or full duplex
0
Full duplex
1
Half duplex
_00000U
Recognition characters,
start & stop characters.
Special characters have to
be download via Instrument
Setup software.
0
* (asterisk) is recognition character.
No start & stop characters.
1
Custom recognition character.
No start & stop characters.
2
* (asterisk) is recognition character.
Special start & stop characters.
3
Custom recognition characters.
Special start & stop characters.
_00000U
RTS mode
0
Normal RTS
1
Single transmission
_00000U
CR (LF) termination cha-
racters.
0
Only at end of all items
1
At end of each item
.
Ser 3
.
Serial Setup 3
_00000U
Data sent in continuous
mode
0
All Active Items
1
Item #1 only
2
Item #2 only (if active)
3
Item #3 only (if active)
4
Peak only
5
Displayed Item
6
Valley only
7
All Active Items + Peak + Valley
___000U
Modbus* ASCII gap timeout
0
1 sec
1
3 sec
2
5 sec
3
10 sec
___000U
Serial protocol
0
Custom ASCII*
1
Modbus* RTU
2
Modbus* ASCII
Ser 4
.
Serial Setup 4
___000U
Parity
0
None
1
Odd
2
Even
_
Addr
Modbus Address
___000 ___000 ___000
Select digit to flash.
__158
Select
0
thru
9
for flashing digit.
Address range is 1 to 247.
* See Glossary for explanation of item.